642445
10
Zoom out
Zoom in
Previous page
1/16
Next page
7 English
Indoor Unit Installation
3-2. Left-side, left-back, or left-bottom piping
How to replace the drain plug and drain hose
•Replacing onto the left side
1)Removetheinsulationxingscrewontheright
andremovethedrainhose.
2)Removethedrainplugontheleftsideand
attachittotherightside.
3)Insertthedrainhoseandtightenwithincluded
insulationxingscrew.
*(Forgettingtotightenthismaycausewater
leakages.)
Drain hose attachment position
* The drain hose is on the back of the unit.
Front side of unit
Attachment on the right side (factory default)
Attachment on the left side
Drain hose Drain hose
Insulation
fixing screw
Insulation
fixing screw
Right sideLeft side
1)Attachthedrainhosetotheundersideoftherefrigerantpipes
withadhesivevinyltape.
Remove pipe port cover here for left-bottom piping.
Remove pipe
port cover
here for left-
side piping.
Left-bottom piping
Left-side
piping
Left-back
piping
2)Besuretoconnectthedrainhosetothedrainportinplaceofa
drainplug.
How to set drain plug
No gap.
Do not apply lubricating
oil (refrigeration oil)
when inserting.
Application of causes
deterioration and drain
leakage of the plug.
Insert a hexagonal wrench (4mm).
3)Shapetherefrigerantpipesalongthepipe
pathmarkingonthemountingplate.
4)Passdrainhoseandrefrigerantpipes
throughthewallhole,thensettheindoor
unitonmountingplatehooks,usingthe
markingsatthetopofindoorunitasa
guide.
5)Pullintheinter-unitwire.
6)Connecttheinter-unitpipes.
Drain
hose
Caulk this hole
with putty or
caulking material.
Bind with adhesive
vinyl tape.
A
Mounting plate
Wrap insulating tape around the
bent portion of refrigerant pipes.
Overlap at least half the width of
the tape with each turn.
7)Wraptherefrigerantpipesanddrainhosetogetherwithinsulationtape
asrightgure,incaseofsettingthedrainhosethroughthebackofthe
indoorunit.
8)Whileexercisingcaresothattheinter-unitwiredonotcatchindoorunit,
pressthebottomedgeofindoorunitwithbothhandsuntilitisrmly
caughtbythemountingplatehooks.Secureindoorunittothemounting
platewithindoorunitxingscrews(M4×12L).
Refrigerant
pipes
Drain hose
Bottom frame
F Indoor unit fixing screw
(M4 × 12L) (2 locations)
Mounting
plate
A
Inter-unit wire
3-3. Wall embedded piping
Followtheinstructionsgivenunderleft-side,left-back,orleft-bottompiping.
1)Insertthedrainhosetothisdepthsoitwon’tbepulledoutofthedrain
pipe.
Inner wall
Vinyl chloride
drain pipe
(VP-30)
Drain hose50mm
or more
Insert drain hose
to this depth so
it won’t be pulled
out of drain pipe.
Outer wall
01_EN_3P320971-1B.indd 7 12/10/2012 4:10:49 PM
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin FTXS50K2V1B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin FTXS50K2V1B in the language / languages: English as an attachment in your email.

The manual is 2,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin FTXS50K2V1B

Daikin FTXS50K2V1B User Manual - English - 44 pages

Daikin FTXS50K2V1B User Manual - German - 44 pages

Daikin FTXS50K2V1B Installation Guide - German - 20 pages

Daikin FTXS50K2V1B Installation Guide - Dutch - 20 pages

Daikin FTXS50K2V1B User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info