Troubleshooting
Fault diagnosis by remote controller
The remote controller can receive from the indoor unit a corresponding error code according
to the fault.
When 1. is held down for about 5 seconds,
a “ ” indication blinks on the temperature
display section.
Press
2. repeatedly until a continuous
beep is produced.
The code indication changes as shown below, and noti es with a long beep.
NOTE
A short beep and two consecutive beeps indicate non-corresponding codes.
To cancel the code display, hold
for about 5 seconds. The code display also cancels itself if the button is not pressed for 1 minute.
CODE
MEANING
SYSTEM
00
NORMAL
U0
REFRIGERANT SHORTAGE
U2
OVER-VOLTAGE DETECTION
U4
SIGNAL TRANSMISSION ERROR (BETWEEN INDOOR AND OUTDOOR UNIT)
INDOOR
UNIT
A1
INDOOR UNIT PCB ABNORMALITY
A5
FREEZE-UP PROTECTION OR HEATING PEAK-CUT CONTROL
A6
FAN MOTOR (DC MOTOR) ABNORMALITY
C4
INDOOR HEAT EXCHANGER THERMISTOR ABNORMALITY
C7
FRONT PANEL OPEN /CLOSE FAULT
C9
ROOM TEMPERATURE THERMISTOR ABNORMALITY
OUTDOOR
UNIT
EA
FOUR WAY VALVE ABNORMALITY
E1
OUTDOOR UNIT PCB ABNORMALITY
E5
OL ACTIVATION (COMPRESSOR OVERLOAD)
E6
COMPRESSOR LOCK
E7
DC FAN LOCK
F3
DISCHARGE PIPE TEMPERATURE CONTROL
H0
COMPRESSOR SYSTEM SENSOR ABNORMALITY
H6
POSITION SENSOR ABNORMALITY
H8
DC VOLTAGE / CURRENT SENSOR ABNORMALITY
H9
OUTDOOR TEMPERATURE THERMISTOR ABNORMALITY
J3
DISCHARGE PIPE THERMISTOR ABNORMALITY
J6
OUTDOOR HEAT EXCHANGER THERMISTOR ABNORMALITY
L4
RADIATION FIN TEMPERATURE RISE
L5
OUTPUT OVERCURRENT DETECTION
P4
RADIATION FIN THERMISTOR ABNORMALITY
01_EN_3P357704-1.indd 3901_EN_3P357704-1.indd 39 12/17/2013 3:22:27 PM12/17/2013 3:22:27 PM
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin FTXG25LV1BS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin FTXG25LV1BS in the language / languages: English as an attachment in your email.

The manual is 32,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin FTXG25LV1BS

Daikin FTXG25LV1BS User Manual - German - 42 pages

Daikin FTXG25LV1BS User Manual - Dutch - 42 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info