Check
Before a long idle period
1. Operate the fan only for several hours on a fine day to dry out the
inside.
Press MODE button and select fanoperation.
Press ON/OFF button and start operation.
2. Clean the air filters and set them again.
3. Take out batteries from the remote controller.
4. Turn OFF the breaker for the room air conditioner.
When a multi outdoor unit is connected, make sure the heating operation is not used at the other room
before you use the fan operation. (page 22)
NOTE
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the earth wire is not disconnected or broken.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the ser-
vice shop if this is the case.
Operation with dirty filters :
(1) cannot deodorize the air. (2) cannot clean the air.
(3) results in poor heating or cooling. (4) may cause odour.
The air purifying filter and photocatalytic deodorizing filter cannot be reused, even if washed.
In principle, there is no need to replace the photocatalytic deodorizing filter. Remove the dust periodi-
cally with a vacuum cleaner. However, it is recommended to replace the filter in the following cases.
(1)
The paper material is torn or broken during cleaning.
(2) The filter has become extremely dirty after long use.
To order air purifying filter or photocatalytic deodorizing filter, contact to the service shop where you
bought the air conditioner.
Dispose of old air filters as non-burnable waste and
photocatalytic deodorizing
filters as
burnable waste.
Part name Part No.
Photocatalytic deodorizing filter and air purifying filter
(with frame)
KAZ926B41
Photocatalytic deodorizing filter (without frame)
KAZ926A42
Air purifying filter (without frame)
KAF926B42
01_EN_3P098574-1D_1.book Page 26 Wednesday, May 7, 2003 4:10 PM
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin FTKS25BVMB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin FTKS25BVMB in the language / languages: English as an attachment in your email.

The manual is 1,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info