554157
12
Zoom out
Zoom in
Previous page
1/24
Next page
4 Operation
User reference guide
12
EHBH/X04+08+16CA + EHVH/X04+08+16CA
Daikin Altherma - Low Temperature Split
4P313778-1B – 2012.11
To read out and adjust the desired reheat
temperature (in reheat mode)
1 Go to the DHW tank temperature home page (Tank).
Result: You can read out the desired reheat temperature.
2 Press or to adjust.
Note: If the desired temperature is weather dependent, you
cannot change it on the home page.
To read out and overrule the active or next
scheduled desired temperature (in scheduled
mode or scheduled + reheat mode)
1 Go to the DHW tank temperature home page (Tank).
Result: or is displayed.
t
a
b
T
t
A1 A2 B1 B2 A1A1 A2 B1 B2 A1
During period… You can read out…
A1 The next scheduled action (a)
A2 The active action (a)
B1 The next scheduled action (b)
B2 The active action (b)
2 Press or to overrule.
Note: If the desired temperature is weather dependent, you
cannot change it on the home page.
Usage example: You need more hot water than
scheduled
If you are in the following situation:
Current time = 10:30
Next scheduled action of the DHW tank = Heat up to the preset
value (Eco; example: 55°C and sufficient for 2 persons) at 14:00
This evening you need hot water for 3 persons
Then you can do the following:
1 Go to the DHW tank temperature home page (Tank).
2 Overrule the next scheduled action by doing one of the
following:
Change from 55°C to 60°C (when defining hot water as
temperature)
Change from 2 persons to 3 persons (when defining hot
water as number of persons)
Advantages:
You will have sufficient hot water (= comfortable).
You do NOT have to change the schedule (= easy).
You do NOT have to activate the DHW tank booster mode
(= energy saving).
4.5.6 Using the DHW tank booster mode
About the DHW tank booster mode
You can use the DHW tank booster mode to immediately start
heating up the water to the preset value (Storage comfort). However,
this consumes extra energy.
To check if the DHW tank booster mode is active
1 Go to the DHW tank temperature home page (Tank).
2 Check the following:
In user profile = Basic: If is displayed, the DHW tank
booster mode is active.
In user profile = Detailed: If is selected, the DHW tank
booster mode is active.
To activate the DHW tank booster mode
(method 1)
1 Go to the DHW tank temperature home page (Tank).
2 Press for more than 2 seconds.
To activate the DHW tank booster mode
(method 2)
Prerequisite: User profile = Detailed
1 Go to the DHW tank temperature home page (Tank).
2 Press
to select .
Usage example: You immediately need more hot
water
If you are in the following situation:
You already consumed most of your hot water.
You cannot wait for the next scheduled action to heat up the
DHW tank.
Then you can activate the DHW tank booster mode.
Advantage: The DHW tank immediately starts heating up the water
to the preset value (Storage comfort).
4.6 Advanced usage
4.6.1 Using quiet mode
About quiet mode
You can use quiet mode to decrease the sound of the outdoor unit.
However, this also decreases the heating/cooling capacity of the
system. There are multiple quiet mode levels.
You can:
Completely deactivate quiet mode
Manually activate a quiet mode level until the next scheduled
action
Use and program a quiet mode schedule
Possible quiet mode levels
Level Description
Level 1 Most quiet. Under all circumstances,
performance will be reduced.
Level 2 Medium quiet. Under all circumstances,
reduced performance is possible.
Level 3 Least quiet. At colder ambient conditions,
reduced performance can be happen.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin EHBX08CA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin EHBX08CA in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin EHBX08CA

Daikin EHBX08CA User Manual - German - 28 pages

Daikin EHBX08CA User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info