587198
32
Zoom out
Zoom in
Previous page
1/34
Next page
31
English
Fault diagnosis.
Fault diagnosis by remote controller
The remote controller can receive a corresponding error code from the indoor unit.
When 1.
is held down for 5 seconds, a “ ” indication blinks on the temperature display section.
Press 2.
repeatedly until a continuous beep is produced.
The code indication changes as displayed in the following table, and noti es with a long beep.
CODE MEANING
SYSTEM
00 NORMAL
U0 REFRIGERANT SHORTAGE
U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR
UNIT
A1 INDOOR PCB DEFECTIVENESS
A5 HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6 FAN MOTOR FAULT
C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9 FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR
UNIT
EA COOLING-HEATING SWITCHING ERROR
E5 OL STARTED
E6 FAULTY COMPRESSOR START UP
E7 DC FAN MOTOR FAULT
E8 OVERCURRENT INPUT
F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL
H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9 FAULTY SUCTION AIR TEMPERATURE SENSOR
J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5 OUTPUT OVERCURRENT
P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR
NOTE
A short beep and two consecutive beeps indicate non-corresponding codes.
To cancel the code display, hold
for 5 seconds. The code display also cancel itself if the button is not pressed for
1 minute.
TIMER CANCEL button
Cancels the timer setting.
01_EN_3P232717-3D.indd 3101_EN_3P232717-3D.indd 31 10/6/2009 9:21:23 AM10/6/2009 9:21:23 AM
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin CTXS07JVJU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin CTXS07JVJU in the language / languages: English as an attachment in your email.

The manual is 1,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info