642453
18
Zoom out
Zoom in
Previous page
1/44
Next page
17
NOTE
Notes on COMFORT AIRFLOW operation
The flaps position will change, preventing air from blowing directly on the occupants of the room.
POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
Priority is given to the function of whichever button is pressed last.
The airflow rate will be set to AUTO. If the upper and lower airflow direction is selected, the COMFORT AIRFLOW operation will be canceled.
Notes on INTELLIGENT EYE operation
Application range is as follows.
While the air conditioner is in INTELLIGENT EYE operation, the louvers will adjust the airflow direction if there are people in the sensing areas
of the INTELLIGENT EYE so that the leftward or rightward airflow will not be directed to the people.
If no people are detected in either area 1 or 2 in 20 minutes, the air conditioner will go into energy-saving mode with the set temperature shifted
by 2°C.
The air conditioner may go into energy-saving operation even if there are people in the areas.
This may occur depending on the clothes the people are wearing if there are no movements of the people in the areas.
The airflow direction from the louvers will be leftward if there are people in both areas 1 and 2 or if there is a person right in front of the sensors
because the sensors on the both sides will detect the person.
Due to the position of the sensor, people might be exposed to the airflow of the indoor unit if they are close to the front side of the indoor unit.
If there are people close to the front side of the indoor unit or in both areas, it is recommended to use the COMFORT AIRFLOW and
INTELLIGENT EYE operations simultaneously. When both of them are in use, the air conditioner will not direct the airflow towards the people.
Sensor may not detect moving objects further than 7m away. (Check the application range.)
Sensor detection sensitivity changes according to indoor unit location, the speed of passersby, temperature range, etc.
The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of mirrors as passersby.
INTELLIGENT EYE operation will not go on during POWERFUL operation.
NIGHT SET mode
Page 21 will not go on during use of INTELLIGENT EYE operation.
Notes on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation
The airflow rate will be set to AUTO. If the upper and lower airflow direction is selected, the COMFORT AIRFLOW operation will be canceled.
Priority is given to the function of whichever button is pressed last.
The flaps adjust the airflow direction upward (while in COOL operation) and downward (while in HEAT operation), during which the sensors of
the INTELLIGENT EYE are working to detect the movement of people. When the sensors detect people, the louvers will direct the airflow in
such way that it will not be blown directly on them. If there are no people, the air conditioner will go into energy-saving operation after
20 minutes.
CAUTION
Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensor’s detection area. This sensor can detect undesirable objects.
Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
Vertical angle 90°
(Side view)
Horizontal angle 110°
(Top view)
COMFORT AIRFLOW /
INTELLIGENT EYE Operation
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin ATXS50K2V1B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin ATXS50K2V1B in the language / languages: English as an attachment in your email.

The manual is 18,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin ATXS50K2V1B

Daikin ATXS50K2V1B Installation Guide - English - 20 pages

Daikin ATXS50K2V1B User Manual - German - 44 pages

Daikin ATXS50K2V1B Installation Guide - German - 20 pages

Daikin ATXS50K2V1B User Manual - Dutch - 44 pages

Daikin ATXS50K2V1B Installation Guide - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info