642468
36
Zoom out
Zoom in
Previous page
1/44
Next page
35
Check the units
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the
case.
Before a long idle period
1.Operate the FAN only for several hours on a fine day to dry out
the inside.
Press and select “ ” operation.
Press and start the operation.
2.After operation stops, turn off the breaker for the room air
conditioner.
3.Clean the air filters and set them again.
4.Take out batteries from the remote controller.
When a multi outdoor unit is connected, make sure the HEAT operation is not used at the other room before you use the
FAN operation.
Page 29
We recommend periodical maintenance
In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor
performance. It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user.
For specialist maintenance, contact the service shop where you bought the air conditioner.
The maintenance cost must be borne by the user.
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Refrigerant type: R410A
GWP
(1)
value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your
local dealer for more information.
Care and Cleaning
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin ATXS25K2V1B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin ATXS25K2V1B in the language / languages: English as an attachment in your email.

The manual is 14,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daikin ATXS25K2V1B

Daikin ATXS25K2V1B Installation Guide - English - 20 pages

Daikin ATXS25K2V1B User Manual - German - 44 pages

Daikin ATXS25K2V1B Installation Guide - German - 24 pages

Daikin ATXS25K2V1B User Manual - Dutch - 44 pages

Daikin ATXS25K2V1B Installation Guide - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info