H9
TERMISTOR DE AIRE EXTERIOR CORTO/ABIERTO
J1
ERROR DEL SENSOR DE PRESIÓN
J3
TERMISTOR DE TUBO DE COMPRESOR DE DESCARGA CORTA/ABIERTA/FUERA DE SITIO
J5
TERMISTOR DEL TUBO DE SUCCIÓN EN CORTO/ABIERTO
J6
TERMISTOR DE INTERCAMBIADOR DE CALOR EXTERIOR CORTO/ABIERTO
J7
TERMISTOR DEL INTERCAMBIADOR DE CALOR DE SUBREFRIGERACIÓN EN CORTO/ABIERTO
J8
TERMISTOR DE TUBO DE LÍQUIDO CORTO/ABIERTO
J9
TERMISTOR DE TUBO DE GAS CORTO/ABIERTO
L1
ERROR DE PCB EXTERIOR DEL INVERSOR
L3
SOBRECALIENTAMIENTO DE CAJA DE CONTROL EXTERIOR
L4
RECALENTAMIENTO DE DISIPADOR TÉRMICO
L5
ERROR IPM/ERROR IGBT
L8
TERMISTOR DEL TUBO DE LÍQUIDO EN CORTO/ABIERTO
L9
TERMISTOR DEL TUBO DE GAS EN CORTO/ABIERTO
LC
ERROR DE COMUNICACIÓN (PCB DE CONTROL EXTERIOR Y PCB INVERSOR)
P1
FASE ABIERTA O DESEQUILIBRIO DE TENSIÓN
P4
TERMISTOR DE DISIPADOR TÉRMICO CORTO/ABIERTO
PJ
ERROR DE CONFIGURACIÓN DE CAPACIDAD
U0
GAS INSUFICIENTE
U2
VOLTAJE CC FUERA DE ALCANCE
U4
ERROR DE COMUNICACIÓN
U7
ERROR DE COMUNICACIÓN (UNIDAD EXTERIOR PCB E IPM PCB)
UA
ERROR DE INSTALACIÓN
UF
DISCORDANCIA DE INSTALACIÓN DE TUBERÍA Y CABLEADO/CABLEADO INCORRECTO/GAS
INSUFICIENTE
UH
ANTICONGELANTE (OTRAS HABITACIONES)
05-ES-OM-GS02-0411(0)-Siesta.ind20 2005-ES-OM-GS02-0411(0)-Siesta.ind20 20 5/20/11 12:00:18 PM5/20/11 12:00:18 PM
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin ARCWLA Remote Control Siesta at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin ARCWLA Remote Control Siesta in the language / languages: English, German, Dutch, French, Italian, Portuguese, Portuguese, Spanish as an attachment in your email.

The manual is 1,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info