CÓDIGO DE
ERROR
SIGNIFICADO
E1 ERROR DE PCB EXTERIOR
E3 PROTECCIÓN DE ALTA PRESIÓN
E4 PROTECCIÓN DE BAJA PRESIÓN
E5 BLOQUEO DEL MOTOR DEL COMPRESOR/COMPRESOR SOBRECARGADO
E6 ERROR DE ARRANQUE DEL COMPRESOR
E7 MOTOR VENTILADOR CC EXTERIOR TRABADO
E8 SOBRECORRIENTE EN ENTRADA DE CA
E9 ERROR EXV
EA ERROR EN VÁLVULA DE 4 VÍAS
F3 SOBRECALENTAMIENTO TUBERÍA DE DESCARGA
F6 SOBRECALENTAMIENTO DEL INTERCAMBIADOR DE CALOR
HO ERROR DEL SISTEMA DEL SENSOR DEL COMPRESOR
H3 ERROR DEL INTERRUPTOR DE ALTA PRESIÓN
H6 ERROR DE DETECCIÓN DE RESPUESTA DEL COMPRESOR
H7
MOTOR DEL VENTILADOR SOBRECARGADO/SOBRETENSIÓN/
ANORMALIDAD DEL SENSOR
H8 ERROR EN SENSOR DE CORRIENTE ALTERNA
H9 TERMISTOR DE AIRE EXTERIOR EN CORTO/ABIERTO
J1 ERROR DEL SENSOR DE PRESIÓN
J3
TUBERÍA DESCARGA DEL COMPRESOR EN CORTO/ABIERTO/MAL
COLOCADO
J5 TERMISTOR DEL TUBO DE SUCCIÓN EN CORTO/ABIERTO
J6
TERMISTOR DEL INTERCAMBIADOR DE CALOR EXTERNO EN CORTO/
ABIERTO
J7
TERMISTOR DEL INTERCAMBIADOR DE CALOR DE SUBREFRIGERACIÓN
EN CORTO/ABIERTO
J8 TERMISTOR DEL TUBO DE LÍQUIDO EN CORTO/ABIERTO
J9 TERMISTOR DEL TUBO DE GAS EN CORTO/ABIERTO
L1 ERROR DE PCB EXTERIOR DEL INVERSOR
L3 SOBRECALENTAMIENTO DE LA CAJA DE CONTROL EXTERIOR
L4 SOBRECALENTAMIENTO DEL DISIPADOR TÉRMICO
L5 ERROR DE IPM/ERROR DE IGBT
L8 SOBRETENSIÓN DEL COMPRESOR INVERSOR
L9 PREVENCIÓN DE SOBRETENSIÓN DEL COMPRESOR
LC
ERROR DE COMUNICACIÓN (PCB DE CONTROL EXTERIOR Y PCB
INVERSOR)
P1 FASE ABIERTA O DESEQUILIBRIO DE TENSIÓN
P4 TERMISTOR DEL DISIPADOR TÉRMICO EN CORTO/ABIERTO
PJ ERROR DE CONFIGURACIÓN DE CAPACIDAD
U0 GAS INSUFICIENTE
U2 TENSIÓN DE CC FUERA DE RANGO
U4 ERROR DE COMUNICACIÓN
U7 ERROR DE COMUNICACIÓN (PCB DE CONTROL EXTERIOR Y PCB IPM)
UA ERROR DE INSTALACIÓN
UF
DISCORDANCIA DE INSTALACIÓN DE TUBERÍA Y CABLEADO/CABLEADO
INCORRECTO/ GAS INSUFICIENTE
UH ANTICONGELACIÓN (OTRAS HABITACIONES)
5-OM-SLM9-0312(0)SIESTA-ES.indd 55-OM-SLM9-0312(0)SIESTA-ES.indd 5 5/4/12 10:42:56 AM5/4/12 10:42:56 AM
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daikin ARCWB-SLM9-0312 Siesta at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daikin ARCWB-SLM9-0312 Siesta in the language / languages: English, German, Dutch, French, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 2,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info