Dahua Network Camera Web 3.0 Operation Manual
89
Parameter
Function
Working Period
Note:
It is to set the alarm period, it can enable alarm event only during the
period range which has been set.
1. Click Setup and the system will pop out the interface of Working
Period.
2. It is to set working period according to the following methods:
You can input time numerical value or press the left mouse button to
drag on the setup interface to set.
There are six periods to be set every day, select the check box in front
of the period, and then the period is valid.
Select week number (it selects Sunday by default, if it selects the
whole week, then it means the setup can be applied to the whole
week, you can also select the check box in front of the week number
to implement independent setting for some days).
3. Click Save to complete the setup of working period.
Anti-dither
System only memorizes one event during the anti-dither period. The value
ranges from 0s to 100s.
Area
1. Click Setup and the system will pop out the interface of Set Area.
2. Set the area name, it is to set the valid area of motion detection
according to the actual situation, and it can set its sensitivity and
threshold respectively. The higher the sensitivity is, the easier it is to
trigger motion detect, the smaller the area threshold is, the easier it is
to generate motion detect, the whole video image is the valid area of
the motion detect by default.
Note:
Different colors represent different areas; each area can set different
detection areas.
The red line in the Oscillogram means triggering motion detect, the green
line means not triggering motion detect.
3. Click Save to complete area setup.
Record
Check it and so when alarm occurs, system will auto record. You shall set
record period in Storage>Schedule and select auto record in record control
interface.
Record Delay
System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.
Relay out
Enable alarm activation function. You need to select alarm output port so
that system can activate corresponding alarm device when alarm occurs.
Alarm Delay
System can delay the alarm output for specified time after alarm ended. The
value ranges from 10s to 300s.
Send Email
If you enabled this function, System can send out email to alert you when
alarm occurs and ends. User can set email address in Network>SMTP.
Audio linkage
Check it and the system will play alarm audio file when alarm occurs. Users
can set the recorded or uploaded audio file in “camera setting audio
alarm audio.
Flash linkage
Check it and the flash will be on when alarm occurs, and the flash will
be off until the end of alarm after corresponding delay.
94


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dahua IPC-PDBW8800-A180 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dahua IPC-PDBW8800-A180 in the language / languages: English as an attachment in your email.

The manual is 7,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dahua IPC-PDBW8800-A180

Dahua IPC-PDBW8800-A180 Quick start guide - English - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info