Storingshulp Warmtepomp
25
26
4.2
Sensorstoringen
Onderbrekingen in sensorcircuits
Slechte verbindingen kunnen worden veroorzaakt door;
Slecht contact tussen kabel en stekker.
Niet goed op elkaar aansluitende stekkers.
Overgangsweerstanden a.g.v. bijvoorbeeld corrosie.
Een interne onderbreking in de sensor
Kortsluiting in sensorcircuits
Bij een kortsluitingen in sensorcircuits meet men extreem lage
weerstandswaarden.
Dit kan veroorzaakt worden;
Gesmolten bedrading.
Interne kortsluiting in de sensor.
Contactbruggen.
4.3
Sensorcircuit controleren
Procedure:
1 Verwijder de stekkers uit de wandcontactdoos.
2 Verwijder de mantel van de warmtepomp van de
CombinAir.
3 Controleer de bedrading naar de sensor visueel op
beschadigingen. Vervang de bedrading eventueel.
4 Verwijder de betreffende connector van de printplaat.
5 Controleer aansluitingen op corrosie of ander slecht
contact.
6 Neem de stekker aan de sensorzijde los.
7 Controleer de betreffende kabels (zie tabel) met een
ohmmeter op een onderbreking of kortsluiting. Vervang de
kabel indien nodig.
8 Controleer de betreffende sensor met een ohmmeter op een
onderbreking of kortsluiting.
9 Vervang de sensor indien nodig.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Daalderop Daalderop CombinAir storingshandleiding at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Daalderop Daalderop CombinAir storingshandleiding in the language / languages: Dutch as an attachment in your email.

The manual is 9,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Daalderop Daalderop CombinAir storingshandleiding

Daalderop Daalderop CombinAir storingshandleiding Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info