Field Description
Authentication The authentication algorithm denes the method used to determine whether a client station
is allowed to associate with an AP when static WEP is the security mode.
Specify the authentication algorithm you want to use by choosing one of the following
options:
•) Open System authentication allows any client station to associate with the AP whether
that client station has the correct WEP key or not. This algorithm is also used in
plaintext, IEEE 802.1X, and WPA modes. When the authentication algorithm is set to
Open System, any client can associate with the AP.
Note: Just because a client station is allowed to associate does not ensure it can exchange
trafc with an AP. A station must have the correct WEP key to be able to successfully access
and decrypt data from an AP, and to transmit readable data to the AP.
•) Shared Key authentication requires the client station to have the correct WEP key in
order to associate with the AP. When the authentication algorithm is set to Shared
Key, a station with an incorrect WEP key will not be able to associate with the AP.
•) Both Open System and Shared Key. When you select both authentication
algorithms:
•) Client stations congured to use WEP in shared key mode must have a valid WEP
key in order to associate with the AP.
•) Client stations congured to use WEP as an open system (shared key mode not
enabled) will be able to associate with the AP even if they do not have the correct
WEP key.
Table 25 - Static WEP
Static WEP Rules
If you use Static WEP, the following rules apply:
•) All client stations must have the Wireless LAN (WLAN) security set to WEP, and all clients must have one of the
WEP keys specied on the AP in order to de-code AP-to-station data transmissions.
•) The AP must have all keys used by clients for station-to-AP transmit so that it can de-code the station
transmissions.
•) The same key must occupy the same slot on all nodes (AP and clients). For example if the AP denes abc123
key as WEP key 3, then the client stations must dene that same string as WEP key 3.
•) Client stations can use different keys to transmit data to the access point. (Or they can all use the same key, but
this is less secure because it means one station can decrypt the data being sent by another.)
•) On some wireless client software, you can congure multiple WEP keys and dene a client station “transfer
key index”, and then set the stations to encrypt the data they transmit using different keys. This ensures that
neighboring APs cannot decode each other’s transmissions.
•) You cannot mix 64-bit and 128-bit WEP keys between the access point and its client stations.
IEEE 802.1X
IEEE 802.1X is the standard dening port-based authentication and infrastructure for doing key management.
Extensible Authentication Protocol (EAP) messages sent over an IEEE 802.11 wireless network using a protocol
called EAP Encapsulation Over LANs (EAPOL). IEEE 802.1X provides dynamically-generated keys that are
periodically refreshed. An RC4 stream cipher is used to encrypt the frame body and cyclic redundancy checking
(CRC) of each 802.11 frame.
This mode requires the use of an external RADIUS server to authenticate users. The AP requires a RADIUS server
capable of EAP, such as the Microsoft Internet Authentication Server. To work with Windows clients, the authentication
server must support Protected EAP (PEAP) and MSCHAP V2.
You can use any of a variety of authentication methods that the IEEE 802.1X mode supports, including certicates,
Kerberos, and public key authentication. You must congure the client stations to use the same authentication method
the AP uses.
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for D-Link DWL-8710AP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of D-Link DWL-8710AP in the language / languages: English as an attachment in your email.

The manual is 7,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info