6 • EN
DESULPHATION SOFT START BULK ABSORPTION ANALYSE RECOND FLOAT PULSE
VOLTAGE (V)
1
1
7
2 3 4 5 6 8
CURRENT (A)
NORMAL
15.8V 60A until 12.6V Increasing voltage to
14.4V
Max 60A
Declining current
14.4V
Checks if voltage
drops below
12V
13.6V
60A
12.7V–14.4V
60A–2A
AGM
15.8V 60A until 12.6V Increasing voltage to
14.7V
Max 60A
Declining current
14.7V
Checks if voltage
drops below
12V
13.6V
60A
12.7V–14.4V
60A–2A
Ca/Ca
15.8V 60A until 12.6V Increasing voltage to
14.7V
Max 60A
Declining current
14.7V
Checks if voltage
drops below
12V
Max 15.8V
1.5A
Initial voltage
>12.3V = 2h,
otherwise 6h.
13.6V
60A
12.7V–14.4V
60A–2A
Time limit: 8 hours 20 hours 8 hours 3 minutes
10days
(Power Supply
unlimited time)
Max 1h pulse
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes sulphates from the
lead plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents charging a defective battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that cannot hold charge may need to be
replaced.
STEP 6 RECOND
Select the Ca/Ca program to add the Recond step to the charging program. During the
Recond step voltage increases to create controlled gassing in the battery. Gassing mixes
the battery acid and gives back energy to the battery.
STEP 7 FLOAT
This step maintains the battery voltage by providing a constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage
and gives a pulse when necessary to keep the battery fully charged.
ACCEPT BULK ABSORPTION ANALYSE COMPLETION MAXIMIZATION FLOAT PULSE
VOLTAGE (V)
1
1
7
2 3 4 5 6 8
CURRENT (A)
Lithium
11.0V
60.0A
60.0A until
13.8V
13.8V Decreasing
current and intelligent
time control
Checks if voltage
drops below 12V
14.4V
Max 1.5A
13.6V
60.0A
Cycle start at 13.3V
13.4V–13.8V
60.0A–2.0A
Cycle start at 13.3V
Limit: Max 30s Max 10h Max 30h 3 minutes
If start charge voltage less than
13.9V then max 2 hours
Max 10 days
Max 1 hour pulse
Auto pulse 10 days
STEP 1 ACCEPT
Tests if the battery can accept charge. This step prevents that charging proceeds with a
defect battery.
STEP 2 BULK
Charging with maximum current until approximately 90% battery capacity.
STEP 3 ABSORPTION
Charging with declining current to maximize up to 95% battery capacity.
STEP 4 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be
replaced.
STEP 5 COMPLETION
Final charge with increased voltage.
STEP 6 MAXIMIZATION
Final charge with maximum voltage up to 100% battery capacity.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage
charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage
and gives a pulse when necessary to keep the battery fully charged.
CHARGING PROGRAMS LEAD-ACID BATTERIES
CHARGING PROGRAMS LITHIUM BATTERIES (LiFePO
4
)
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ctek PRO 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ctek PRO 60 in the language / languages: English as an attachment in your email.

The manual is 4,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ctek PRO 60

Ctek PRO 60 User Manual - German - 6 pages

Ctek PRO 60 User Manual - Dutch - 6 pages

Ctek PRO 60 User Manual - French - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info