Exhaust of waste gases through the chimney should be of continuously ascending placing.
Maximum length of waste gas outlet is 2,000 mm. The maximum difference of height between
the upper edge of the oven for baking and the outlet of waste gases is 1,500 mm. For ducting the
exhaust gases over a side wall stack, the minimum elevation difference is 150 mm, and 200 mm
for a Truma roof stack.
Walls and integral parts whose distance from waste gas exhaust pipe is less than 50 mm should
be either lined or protected with materials belonging to the group of fire resistance M0.
At the output from the oven and at the input to the stack extension, the exhaust from the flexible
metallic pipe with a diameter of ∅ 55 mm must be attached with a worm hose clamp (a Truma
clamp is convenient for the given ∅ 50 – ∅ 60 mm pipe), or with the attachment screw supplied
along with the Truma roof stack.
THE DEVICE SHOULD BE PLACED OUT OF REACH OF EASILY INFLAMMABLE
MATERIALS.
7.2 PROTECTION FROM OVERHEATING
All conditions for installation of the facility described under the point 7.1. are necessary to be
adhered to.
7.3 TAKING THE DEVICE OUT OF FURNITURE
a) Close the main gas valve.
b) Loosen fixing screws.
c) Loosen gas connection and possible electrical cables.
8. USE THE DEVICE ONLY IN A WELL AERATED ROOM
During operation of the appliance, the aeration openings have to be clear.
9. USING THE OVEN
ATTENTION: please push up the lock handle with thumb to open the door. At shutting of the
door the handle locks door automatically.
9.1 IGNITION OF THE OVEN
The oven is equipped with an electronic stroke spark ignition system.
a) To light the oven or the grill, the door of the oven must be fully open.
b) Press the turn button lightly and turn it to the left to the ignition position. The oven may
be lit at any position of the turn button. After igniting flame, still hold the button pressed
for the time of about 10 seconds. The lighting of the grill (for an oven with grill) can be