User and installation instructions
Contents of this document
1. Important safety instructions
2. Installation instructions
3. User manual
4. Technical specifications
1. Important safety instructions
While using the Cosiloft these safety instructions should always be followed to reduce the risk of fire and other
damage to people and property. Read these safety instructions carefully before the Cosiloft is put into operation.
1. The Cosiloft should always be installed correctly and in accordance with the supplied installation
instructions. The Cosiloft must be placed in a straight position on a hard, stable surface.
2. Only use the type of gas and the type of cylinder specified in these instructions.
3. The device must be placed far away from flammable materials (min. 2 meters) and the area around the
appliance must be clear of combustible materials and/or liquids.
4. Before using the Cosiloft, check whether all connections to the gas bottle are fitted securely. Also ensure
that the regulator seal is fitted correctly and able to fulfil its function. If the connections are not
connected securely, make sure everything is fixed and tied before use. Make sure that the gas is turned
off while fixing.
5. Change the gas cylinder in an amply ventilated area, away from any ignition sources (candle, cigarettes,
other flame producing appliances).
6. Every time the gas connection is re-connected, or at least once per month, the gas connection and the
hose must be checked for leaks. The hose or the flexible hose must be changed within the prescribed
intervals. See chapter 2.5.
7. The hose must never make contact with the hot surface of the burner.
8. The hose must comply with the national laws and regulations (EN 16436). The hose will be connected
to the supplied gas pressure regulator. Do not connect the gas bottle directly to the appliance without
regulator.
9. The pressure regulator is set for 28-30mbar, 37mbar or 50mbar, and the regulator outlet pressure is 28-
30mbar, 37mbar or 50mbar. The gas regulator has to be set according to the specific gas category (see
data figure). The regulator should comply with EN 16129 standard.
10. Never change the air valve settings of the burner. If the air vents of the fire rings are obstructed,
immediately contact a technical gas specialist for help.
11. In the event of gas leakage, the appliance may not be used. If it’s already in operation, the gas supply
must be shut off and the appliance shall be investigated and rectified before it is used again.
12. Never obstruct the free flow of air and oxygen to the device. Never change anything to the technical gas
system of this unit. Any change to the system can be dangerous and will void any warranty on the device.
13. The injector in this appliance may not be removed and the injector can only be installed by the
manufacturer.
14. This appliance is not allowed to switch from one amount of gas pressure to another amount of gas
pressure.
15. Keep children and pets at a safe distance from the unit. The Cosiloft has components that become very
hot when in use. Wait until the appliance has cooled down sufficiently before allowing children and pets
to come within the vicinity of the device. Our recommendation is to wait at least 1.5 hours.
16. Never move the Cosiloft if the device is turned on. Wait at least 1.5 hours after the device has been
turned off before moving it. Shut the valve of the gas cylinder or the regulator before moving the
appliance.
17. Never leave the Cosiloft unsupervised while it’s in operation.
18. The device has an open fire, so make sure that children and pets are always supervised by a mature and
responsible person while using the Cosiloft.
19. Do not touch the lava rocks and ceramic logs until they are completely cooled down.
20. Turn off the gas supply when the device is not in use.
21. Wait at least 1 hour after the device has been turned off before placing the SS cover on the unit. If the
cover is placed before the Cosiloft is complete cooled down damage to the cover or even fire may occur.
22. The Cosiloft is designed to bring warmth and should only be used outdoors.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cosi Cosiloft 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cosi Cosiloft 120 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info