2. INSTALLATION
Before contacting the local Authorised
Service Provider for the installation
of the dryer, check the information in
the user manual to make sure that the
electrical installation and water outlet is

electrician and a plumber to have the
necessary adjustments made.
It is the customers responsibility to
prepare the dryers installation place, as
well as the electricity and waste water
installation. Before installation, check
the dryer for damage. If damaged, do
not have it installed. Damaged products
may endanger your health.

surface.
Run the dryer in a dust-free
environment where the air ventilation
is good.
The clearance between the dryer and
should not be reduced with
objects such as carpets, wood or tape.
Do not block the ventilation grills
found on the plinth of the tumble dryer.
The appliance must not be installed
behind a lockable door, a sliding door
or a door with a hinge on the opposite
side of the tumble dryer, in such a
way that blocks the full opening of the
tumble dryer door.
Once the dryer has been installed, the
connections must remain stable. When
installing the dryer, make sure that the
rear surface is not leaning on anything
(e.g. tap, socket).
The operating temperature of the dryer
is +5°C to +35°C. If operated out of this
temperature range, the performance of
󰀨
the product will be damaged.
Be careful when carrying the product
since it is heavy. Always wear safety
gloves.
Always install the product should be
placed against a wall.
The rear surface of the product should
be placed against the wall.
When the product is placed on a stable
surface, use a water level to check if it
is fully stable. If not, adjust the feet until
it becomes steady. Repeat this process
every time you relocate the product.
Do not place the dryer onto the power
cable.
2.1. Removing the Safety Assembly
Open the loading door.
Hold the nylon that contains the
Styrofoam part and is found in the
drum.
Pull the nylon towards you and remove
the transport safety assembly.
Make sure that there is no part of the
transport safety assembly left in the
drum.
2.2. Connection to Water Outlet (with
optional drain hose)
In products with a condenser unit, water
accumulates in the water tank during
the drying process. You must empty the
accumulated water after each drying
process. Instead of periodically emptying
the water tank, you can also use the water
drain hose provided with the product to
directly drain the water outside.
2.2.1. Connecting the Water Discharge
Hose
1. Pull and take out the end of the hose at the
back of the dryer. Do not use any tools to
take out the hose.
2. 


3. 
.
ATTENTION: The hose must be
connected in a manner that it cannot be
displaced. If the hose comes out during

your house.
2
1
3
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Corbero CSCEV8007 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Corbero CSCEV8007 in the language / languages: English as an attachment in your email.

The manual is 5,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Corbero CSCEV8007

Corbero CSCEV8007 User Manual - Spanish - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info