574403
13
Zoom out
Zoom in
Previous page
1/16
Next page
10
PlugtheexternalprobeintotheUSBsocketwhichliesinthedevice,andtheaffiliatedprobeofthe
devicewouldbecomeinvalidationimmediately,thedatawhichisshownonthescreenismeasured
bytheexternalprobe,ifunplugtheexternalprobefromthedevice,theaffiliatedprobewill
automaticallybecomeeffective.
I
I
I
I
n
n
n
n
the
the
the
the
condition
condition
condition
condition
of
of
of
of
external
external
external
external
probe,
probe,
probe,
probe,
even
even
even
even
if
if
if
if
the
the
the
the
device
device
device
device
cannot
cannot
cannot
cannot
detect
detect
detect
detect
any
any
any
any
signal,
signal,
signal,
signal,
it
it
it
it
would
would
would
would
not
not
not
not
power
power
power
power
off.
off.
off.
off.
F.Charge
Charge
Charge
Charge
Therearetwokindsofchargingmethods:
aConnectthedevicewithcomputerbydataline,thenthedeviceshouldbeunderchargingstate.
bConnectthedevicewithpowersupplybypoweradaptor,thenthedeviceshouldbeundercharging
state.
cWhenthedeviceisinthestateofbatterycharging,theindicationlightison,whenthebattery
capacityisfull,theindicationlightwouldbeoffaccordingly.
If
If
If
If
the
the
the
the
alarm
alarm
alarm
alarm
function
function
function
function
is
is
is
is
on
on
on
on
,
,
,
,
the
the
the
the
device
device
device
device
will
will
will
will
provide
provide
provide
provide
high-priority
high-priority
high-priority
high-priority
alarm
alarm
alarm
alarm
signal
signal
signal
signal
when
when
when
when
the
the
the
the
battery
battery
battery
battery
is
is
is
is
in
in
in
in
low
low
low
low
power
power
power
power
status
status
status
status
and
and
and
and
intermittent
intermittent
intermittent
intermittent
alarm
alarm
alarm
alarm
will
will
will
will
occur.
occur.
occur.
occur.
6
6
6
6
.2
.2
.2
.2
.
.
.
.
Attention
Attention
Attention
Attention
for
for
for
for
operation
operation
operation
operation
A.Pleasecheckthedevicebeforeusing,andconfirmthat
it
canworknormally.
B
B
B
B
.Thefingershouldbeinaproperposition(seetheattachedillustrationoffigure3forreference),
orelse
it
mayresultininaccuratemeasure.
C
C
C
C
.TheSpO
2
sensorandphotoelectricreceivingtubeshouldbearrangedinawaywiththesubject
s
arterioleinapositiontherebetween.
D
D
D
D
.TheSpO
2
sensorshouldnotbeusedatalocationorlimbtiedwitharterialcanalorblood
pressurecufforreceivingintravenousinjection.
E
E
E
E
.DonotfixtheSpO
2
sensorwithadhesiveorelse
it
mayresultinvenouspulsationandinaccurate
measureofSpO
2
andpulserate.
F
F
F
F
.Excessiveambientlightmayaffectthemeasuringresult.Itincludesfluorescentlamp,dualruby
light,infraredheater,directsunlightandetc.
G
G
G
G
.Strenuousactionofthesubjectorextremeelectrosurgicalinterferencemayalsoaffectthe
accuracy.
H
H
H
H
.Testeecannotuseenamelorothermakeup.
I
I
I
I
.PleasecleananddisinfectthedeviceafteroperatingaccordingtotheUserManual(6.1).
6
6
6
6
.3
.3
.3
.3
.
.
.
.
Clinical
Clinical
Clinical
Clinical
restrictions
restrictions
restrictions
restrictions
A.Asthemeasureistakenonthebasisofarteriolepulse,substantialpulsatingbloodflowofsubject
isrequired.Forasubjectwithweakpulseduetoshock,lowambient/bodytemperature,major
bleeding,oruseofvascularcontractingdrug,theSpO
2
waveform(PLETH)willdecrease.Inthiscase,
themeasurementwillbemoresensitivetointerference.
B
B
B
B
.Forthosewithasubstantialamountofstainingdilutiondrug(suchasmethyleneblue,indigo
greenandacidindigoblue),orcarbonmonoxidehemoglobin(COHb),ormethionine(Me+Hb)or
thiosalicylichemoglobin,andsomewithicterusproblem,theSpO
2
determinationbythismonitor
maybeinaccurate.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Contec CMS-50E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Contec CMS-50E in the language / languages: English as an attachment in your email.

The manual is 0,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info