en
22
– Install built-under or integratable
appliances only under continuous
worktops which have been screwed to
adjacent cupboards to ensure stability.
– Do not install the appliance near heat
sources (radiators, heat storage tanks,
cookers or other appliances which
generate heat) and do not install under
a hob.
– After installing the appliance, ensure
that the plug is easily accessible.
–Some models:
The plastic housing on the water
connection contains an electric valve,
the connecting cables are in the supply
hose. Do not cut through this hose, do
not immerse the plastic housing in
water.
ã=Warning
If the appliance is not in a cavity and a
side panel is accessible, the door hinge
area must be covered at the side for
reasons of safety (risk of injury). The
covers are available as optional
accessories from customer service or
specialist outlets.
Delivery
Your dishwasher has been checked
thoroughly in the factory to ensure that it is
in working order. This may cause small
water stains. These will disappear after the
first wash cycle.
Technical specifications
Weight:
max. 53 kg
Voltage:
230 V, 50 Hz
Connected load:
2,3 kW
Fuse:
10/13 A
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1MPa (10bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature
60 °C.
Installation
The required installation dimensions can
be found in the installation instructions.
Level the appliance with the aid of the
height-adjustable feet. Ensure that the
appliance is situated securely on the floor.
– A built-under or integrated appliance
which is installed subsequently as a
free-standing appliance must be
secured to prevent it from overturning,
e.g. by screwing it to the wall or by
installing it under a continuous worktop
which is screwed to adjacent
cupboards.
– The appliance can easily be installed in
a fitted kitchen between wooden and
plastic walls. If the plug is not freely
accessible, an allpole disconnector
with a contact opening of at least 3 mm
must be fitted on the installation side to
satisfy the relevant safety instructions.