596597
23
Zoom out
Zoom in
Previous page
1/26
Next page
en
23
Installation
The dishwasher must be connected by
a qualified technician to ensure correct
operation. The specifications for supply,
drainage and connected load must fulfil
the required criteria as stated in the
following paragraphs or in the installation
instructions.
Install the appliance in the following
sequence:
– Check the delivery
– Install the appliance
– Connect the waste water
– Connect the fresh water
– Connect the power supply
Delivery
Your dishwasher was checked at the
factory to ensure that it was in perfect
working order. This may have left some
small water stains in the dishwasher.
These will disappear after the first rinse
cycle.
Installation
The required installation dimensions can
be found in the installation instructions.
Using the height-adjustable feet, adjust the
appliance until it is level. Ensure that the
appliance is standing firmly.
Waste water connection
See the installation instructions for the
required connection steps. If required,
attach a siphon with drainage spigot.
Using the enclosed parts, connect the
waste water hose to the drainage spigot
of the siphon.
Ensure that the drainage hose is not
kinked, crushed or twisted (ensure that
there is no sealing cover which prevents
the waster water from flowing away!).
Fresh water connection
Using the enclosed parts, connect the
fresh water connection to the tap
according to the installation instructions.
Ensure that the fresh water connection is
not kinked, crushed or twisted.
When replacing the appliance, always
connect a new water supply hose to the
water supply. The old supply hose must
not be re-used.
Ensure that the fresh water connection is
not kinked, crushed or twisted.
Water pressure:
Minimum 0,5 bar – maximum 10 bar.
If the water pressure is higher, install a
pressure reducing valve.
Flow rate:
Minimum of 10 litres per minute.
Water temperature:
We recommend that you use cold water.
If you do use hot water, the temperature
should not exceed 60 °C.
Electrical connection
This appliance should only be connected
to a 230/240 V AC source via a properly
installed earthed socket. See nameplate
31 for size of required fuse.
The socket must be installed close to the
dishwasher.
If the domestic wiring includes a residual-
current-operated (FI) circuit-breaker, make
sure that it bears the
mark, as only
this type conforms to the latest regulations
Disconnecting the dishwasher
Here too, it is important that tasks are
carried out in the correct sequence:
always unplug the appliance from the
mains electricity first of all.
Pull plug out of wall socket.
Turn off water supply.
Disconnect drain and water input hoses.
Remove screws in underside of work
surface. Detach base board, if fitted.
Pull out appliance and carefully withdraw
hoses at same time.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Constructa CG562J5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Constructa CG562J5 in the language / languages: English as an attachment in your email.

The manual is 2,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Constructa CG562J5

Constructa CG562J5 User Manual - German - 26 pages

Constructa CG562J5 User Manual - Dutch - 26 pages

Constructa CG562J5 User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info