In any case, consult your responsible
Master Chimney Sweep. He is able to
assess the house's entire ventilation setup
and will suggest the suitable ventilation
measures to you.
Unrestricted operation is possible if the
vapour extractor hood is operated
exclusively in the circulating-air mode.
Danger of death!
Risk of poisoning from flue gases that are
drawn back in. If installing a ventilation
system in a room with a heat-producing
appliance connected to a chimney/flue, the
electricity supply to the hood must be
equipped with a suitable safety switch.
Risk of injury!
■
Components inside the appliance may
have sharp edges. Wear protective gloves.
Risk of injury!
■
The appliance may fall down if it has not
been properly fastened in place. All
fastening components must be fixed firmly
and securely.
Risk of injury!
■
The appliance is heavy. To move the
appliance, 2 people are required. Use only
suitable tools and equipment.
Risk of injury!
■
Changes to the electrical or mechanical
assembly are dangerous and may lead to
malfunctions. Do not make any changes
to the electrical or mechanical assembly.
Hazard due to magnetism!
Permanent magnets are inserted in the
appliance front. They may affect electronic
implants, e.g. heart pacemakers or insulin
pumps. Wearers of electronic implants must
stay at least 10 cm away from the
appliance front.
Risk of electric shock!
■
Components inside the appliance may
have sharp edges. These may damage
the connecting cable. Do not kink or pinch
the connecting cable during installation.
Risk of electric shock!
■
It must always be possible to disconnect
the appliance from the power supply. The
appliance must only be connected to a
protective contact socket that has been
correctly installed. If the plug can no
longer be reached after installation, an
energy-isolating device in the phases must
be provided in the permanent electrical
installation in accordance with the
installation regulations. The permanent
electrical installation must only be wired
by a professional electrician. We
recommend installing a residual-current
circuit breaker (RCCB) in the appliance's
power supply circuit.
Risk of electric shock!
Incorrect repairs are dangerous. Repairs
may only be carried out and damaged
power cables replaced by one of our
trained after-sales technicians. If the
appliance is defective, unplug the appliance
from the mains or switch off the circuit
breaker in the fuse box. Contact the after-
sales service.
Danger of suffocation!
Packaging material is dangerous to
children. Never allow children to play with
packaging material.