743662
61
Zoom out
Zoom in
Previous page
1/63
Next page
TDMA CONTROL 601/701:
61
Published 07/2007
6 CONTROL 701 Technical Data
Basic Instrument:
Plastic casing, 300 x 160 x 120 mm
Fuse type:
IP 65
Operational voltage:
230 V ±10%, 50... 60 Hz, AC
Uptake:
max. 10 VA
Interference following:
EMI guidelines
Electricity guidelines:
DIN EN: 61010-1; 55022; 50082-1; 61326; 61000-4-2; 61000-4-3; 61000-4-
4; 61000-4-5; 61000-4-6; 61000-4-11
Switch contact / Relay:
A1-A14: 230 V / 2A Triac
A15-A16: potentialfreies Umschaltrelais 230 V / 2 A
Output fuses:
A1 - A4 sind gemeinsam mit 2,5 A abgesichert.
A5 - A9 sind gemeinsam mit 2,5 A abgesichert.
A10 - A14 sind gemeinsam mit 2,5 A abgesichert.
Control
menu lead
Service Menu:
Every output can be operated manually.
Measurement register:
Dependant on sensor type
Accuracy
± 1K (in the range 0 ... 100°C)
Temperature sensor PT 1000
(RE040):
-30 °C ... 180 °C Continuous temperature, 250 °C temporarily
Temperature sensor PT
1000(RE0
(RE046):
-30 °C ... 80 °C Continuous temperature
Temp. in °C
-10
0
10
20
30
40
50
60
70
80
90
100
110
R in Ohm
961,5
1000
1038,5
1077
1115,5
1154
1192,5
1231
1269,5
1308
1346,5
1385
1423,5
Operating temperature regu-
lator:
0°C…40°C
CONTROL 701 Operational Status Indicators
Symbol:
Description
Symbol:
Description
Operation
Holiday operation
Top loading
(Stratified loading function)
Override/Party switch acti-
ve
Night time temperature
drop active
Circulation active
Winter operation (Heating
+ Hotwater)
Sensor fault
Summer operation (only
Hotwater)
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Consolar Control 601 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Consolar Control 601 in the language / languages: English as an attachment in your email.

The manual is 5,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info