6.4.6 Removal and installation of the drain pump
For removing the drain pump the steam cylinder must be removed rst (see chapter 6.4.3).
1. Detach electric cables (polarity of the cables must not be observed).
2. Release hose clamps and remove the hoses from the connectors.
3. Undo the two screws on the bottom of the housing with Phillips screwdriver, then remove drain pump.
4. Separate the electric motor from the pump body: release the lock on the bayonet catch, then counter-
rotate the electric motor and the pump body. Remove O-ring.
The assembly and the installation of the drain pump follows the reverse sequence of the removal. Before
assembling the pump, check O-ring for damage and replace if necessary. Then, place the O-ring on the
centering collar and moisten the O-ring with water.
1
2
3
4
61


Need help? Post your question in this forum.

Forumrules
1

Forum

condair-rs

Reset search

  • why drain hose led to left, is it due to electrical on right side.
    Submitted on 29-8-2022 at 23:32

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Condair RS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Condair RS in the language / languages: English as an attachment in your email.

The manual is 5,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Condair RS

Condair RS Installation Guide - English - 80 pages

Condair RS User Manual - Dutch - 80 pages

Condair RS Installation Guide - Dutch - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info