652344
57
Zoom out
Zoom in
Previous page
1/80
Next page
57Mounting and installation work
L1 L2 L3
L1 L2 L3 PE
Q5
F5
200-600 V/3~/50..60 Hz
200-240 V/1~/50..60 Hz
L1 N PE
Q5
F5
L1 L2 L3
K1
X0
140Ω...10kΩ
A2
On/Off
A3
GND
IN
V+
IN
V+
B3
K2
B2
B1
L1 N PE
F6
Q6
230 V/1~/50..60 Hz
J3
230V/5A
A4
+ +
A1
JP1
24V 10V
JP1
24V 10V
J1
L1 N PE
M
L2 L3L1
L1 N PE
L1 L2 L3 PE
Q5
F5
L2 L3
L1
N PEL1
L1 L2 L3 N
Q5
F5
PE
PEPESC2SC1NL1
INLET SPARE/DRAIN
CONTA.
CONT. SIGN.
GNDINV+
24V
10V
CONT.INLET
L1FU
L1SW
N
MAIN SUPPLY
MODULE B
PEP1NP
LIM. SIGN.
GNDIN
SPARE DRAIN
SWITCH
L1SCNSW L1SCNSW L1SWNSW L1SW
F1 (1 AT)
COMM
HB OK
JP3
JP1
LEVEL
LOW 24V GND
CURRENT SENSOR
SC OK
HWS
BLOWER
IN24V
ON/OFF
IN24V
SPARE1SPARE2T1
D+GND
D-
GND24V
D+
GND D-
RS4852RS4851PWR IC
SW1
F3 (4 AT)
3V
CR2032
GND + GND + GND + 24V GND
BMSLinkupSABJ14
(USB)
(RJ45)
BAT
SD
J7
J4J8J11
ACCESSORY BOARD
REMOTE BOARD
F1 (100 mA)
H1
Error
1 2 3
Service
4 5 6
Steam
7 8
Unit On
9 10
H2
Hyg. Valve A FAN B
1 2 3
Hyg. Valve B
4 5 6
7 8
FAN A
9 10
Y Z
B4
Control compartment
5.7.2 Wiring diagram Condair EL 5...45 - Single units "S" and "M"
Fig. 26: Wiring diagram Condair EL 5...45 - Single units "S" and "M"
A1 Continuous humidity controller (active) or humidity sensor
A2 Ohmic humidity ontroller (passive), set jumper JP1 to 10V
A3 On/Off humidity controller, set jumper JP1 to 24V
A4 Limiter signal
B1 Ventilation interlock
B2 Airow monitor
B3 Safety humidistat (highly recommended)
B4 External enable contact
F1 Internal fuse driver board 24V supply (1 A, slow acting)
F3 Internal fuse driver board 230V supply (4 A, slow acting)
F5 External fuse heating voltage supply (see table in chapter 5.7.7)
F6 External fuse control voltage (max. 10 A, slow acting)
H1 Remote operating and fault indication (option)
H2 Accessory board (option) for the control of an external fan of the AHU as well
as the optional external valve for the water supply line ushing
J1 Jumper wire, if blower pack safety loop is not connected
J3 Jumper wire, if no monitoring devices are connected to SC1 and SC2
J4 Jumper for activating the termination resistor for Modbus or BACnet MSTP
network (Jumper must be connected, if the Condair EL is the rst or the last
unit in the network)
J7 Jumper for activating Modbus or BACnet MSTP communication via RS485
interface (J6). If jumper is not in place no communication will take place
through the RS485 interface.
K1 Mains contactor (heating voltage) unit A/unit B
K2 External safety circuit (230V/5A)
M Motor blower pack
Q5 External electrical isolator heating voltage supply
Q6 External electrical isolator control voltage supply
SW1 Rotary switch module identication (must be left on position "0" Module A)
X0 Terminal Heating voltage supply (option)
Control board
Driver board
Option TR (3Ph)
Option CVI (3Ph+N)
6.3 A, slow acting
6.3 A, slow acting
Ethernet (RJ45)
IP network / BMS BACnet IP
RS 485
BACnet MSTP
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Condair EL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Condair EL in the language / languages: English as an attachment in your email.

The manual is 4,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Condair EL

Condair EL User Manual - English - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info