TABLE FOR INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
P
Model identier(s): RO3311 – NY2311-20M
Item Symbol Value Unit Item Unit
Heat output Type of heat input, for electric storage local space heaters only
(select one)
Nominal heat output Pnom 1.0 kW Manual heat charge control with integrated
thermostat
[no]
Minimum heat
output (indicative)
Pmin 0.9 kW Manual heat charge control with room and/or
outdoor temperature feedback
[no]
Maximum
continuous heat
output
Pmax 1.0 kW Electronic heat charge control with room and/or
outdoor temperature feedback
[no]
Auxiliary electricity consumption Fan assisted heat output [no]
At nominal heat
output
elmax 0.000 kW Type of heat output/room temperature control (select one)
At minimum heat
output
elmin 0.000 kW Single stage heat output and no room temperature
control
[no]
In standby mode elSB 0.000 kW Two or more manual stages, no room temperature
control
[no]
With mechanic thermostat room temperature
control
[yes]
With electronic room temperature control [no]
Electronic room temperature control plus day timer [no]
Electronic room temperature control plus week timer [no]
Other control options (multiple selections possible)
Room temperature control, with presence detection [no]
Room temperature control, with open window
detection
[no]
With distance control option [no]
With adaptive start control [no]
With working time limitation [no]
With black bulb sensor [no]
Contact details:
Jindrich Valenta - Concept
Vysokomytska 1800
565 01 Chocen, CZECH REPUBLIC
Remark:
For electric local space heaters, the measured seasonal space heating energy eciency ηs cannot be worse
than the declared value at the nominal heat output of the unit.
The seasonal space heating energy eciency of all local space heaters except commercial local
space heaters, ηs (%)
36
TABLE FOR INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
P
Model identier(s): RO3309 – NY2009-20M
Item Symbol Value Unit Item Unit
Heat output Type of heat input, for electric storage local space heaters
only (select one)
Nominal heat output Pnom 0.8 kW Manual heat charge control with integrated
thermostat
[no]
Minimum heat
output (indicative)
Pmin 0.7 kW Manual heat charge control with room and/or
outdoor temperature feedback
[no]
Maximum
continuous heat
output
Pmax 0.8 kW Electronic heat charge control with room and/or
outdoor temperature feedback
[no]
Auxiliary electricity consumption Fan assisted heat output [no]
At nominal heat
output
elmax 0.000 kW Type of heat output/room temperature control (select one)
At minimum heat
output
elmin 0.000 kW Single stage heat output and no room
temperature control
[no]
In standby mode elSB 0.000 kW Two or more manual stages, no room
temperature control
[no]
With mechanic thermostat room temperature
control
[yes]
With electronic room temperature control [no]
Electronic room temperature control plus day
timer
[no]
Electronic room temperature control plus week
timer
[no]
Other control options (multiple selections possible)
Room temperature control, with presence
detection
[no]
Room temperature control, with open window
detection
[no]
With distance control option [no]
With adaptive start control [no]
With working time limitation [no]
With black bulb sensor [no]
Contact details:
Jindrich Valenta - Concept
Vysokomytska 1800
565 01 Chocen, CZECH REPUBLIC
Remark:
For electric local space heaters, the measured seasonal space heating energy eciency ηs cannot be worse
than the declared value at the nominal heat output of the unit.
The seasonal space heating energy eciency of all local space heaters except commercial local
space heaters, ηs (%)
36
ENEN
6160 RO3307 | RO3309 | RO3311RO3307 | RO3309 | RO3311
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Concept RO3307 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Concept RO3307 in the language / languages: English, German, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info