1. Before plugging in the appliance, make sure that the main switch I/O is in the O (O) position.
2. Place the heater on a solid stable surface and switch the main switch to the I position (On). You will hear a sound
signal, the device is in the standby mode.
3. Press the On/Off button on the remote control or START/STOP directly on the appliance to turn on the heater -
operating mode.
Time and date setting (only in operating mode)
1. Press the Set button (11m) and by pressing the +/- buttons (9i/10l) set the day.
2. Press the Set button for the second time (11m) and by pressing the +/- buttons (9i/10l) set the hour.
3. Press the Set button for the third time (11m) and by pressing the +/- buttons (9i/10l) set the minute.
4. Press the Set button for the fourth time (11m) – time and date are saved.
Note: If there is a delay of more than 5 seconds between each pressings of the buttons, the current setting will be
saved automatically.
Warning: When the appliance is turned off by pressing the main button O/I, due to a power failure or unplugged
power cord, the time and date settings will be lost.
Manual operating mode setting (only in operating mode)
1. Press the On/Off button (1a) and put the device into operating mode.
2. Press the Mode button (2b) and select the desired mode:
- Warm air, power 1000 W (C)
- Hot air, power 2000 W (D)
- Fan function (no icon on the display)
3. Press the Swing button (4d) to activate/deactivate automatic air oscillation.
Automatic operating mode setting (only in operating mode)
In this mode the appliance automatically selects the desired mode according to the set/ambient room temperature.
1. Press the +/- buttons(9i/10l) to select the desired temperature from 10 to 49 °C. The ST icon is active during setting
(H).
2. The selected option is automatically saved after 5 seconds. The ST icon (H) goes out, the RT icon lights up (G)
3. Press the Mode button to deactivate (2b) and select the desired mode (min/max/fan)
Note: If the temperature drops 2 degrees below the set temperature, the heater switches to warm airow (1000 W).
If the temperature drops 4 degrees below the set temperature, the heater switches to hot airflow (2000 W). If the
temperature rises 1 or more degrees above the set temperature, the heater switches to cold airow.
Day timer setting (only in operating mode)
1. Press the 24H button (5e) and by repeated pressings of the button set the desired shut down time (1 – 24 hours).
2. The day timer is active if the clock icon is lit on the display (P).
3. To deactivate the timer, press the 24H button again (5e) until the time 00 appears on the display, the clock icon (P)
is inactive.
Week timer setting (only in operating mode)
The week timer allows you to set the temperature and mode for each day of the week.
1. Press the W-Timer button (8h) and by pressing the +/- buttons (9i/10l) select the day (MO-SU).
2. Press the W-Timer button for the second time (8h) a and by pressing the +/- buttons (9i/10l) select the hour of
start (00-24).
3. Press the W-Timer button for the third time (8h) a by pressing the +/- buttons (9i/10l) select the minute of start
(00-59).
4. Press the W-Timer button for the fourth time (8h) a by pressing the +/- buttons (9i/10l) select the hour of shut
down (00-24).
5. Press the W-Timer button for the fifth time (8h) a and by pressing the +/- buttons (9i/10l) select the minute of shut
down (00-59).
6. Wait 5 seconds, the W icon (O) is active.
Note: You can set all days of the week in the same way.
7. Press the Delay button to set the temperature (7g) and by pressing the +/- buttons (9i/10l) select the desired
temperature (10-49 °C)
8. The week time is active if the W icon is lit on the display (O) and the current ON/OFF status (L/M) appears on the
display.
9. Press the W-Timer button to deactivate the week timer (8h). The ON, ON (OFF) icons are inactive.
Warning: When the appliance is turned off by pressing the main button O/I, due to a power failure or unplugged
power cord, the time and date settings will be lost.
Warning: If there is a delay of more than 5 seconds, the current setting is automatically saved.
Open window function setting (only in operating mode)
This function stops the operation of the appliance if the ambient temperature drops by at least 3 °C within 1 minute.
1. Press the AUTO button to activate it (3c). The open window icon (P) will appear on the display.
2. Press the AUTO button to deactivate it (3c). The open window icon (P) goes out.
Child lock setting (only in operating mode)
1. Press the Lock button to activate it (6f). Only one icon is lit on the display (A).
2. In this mode, only the ON/OFF (1a) and Lock (6f) buttons work.
3. Press the Lock button to deactivate it (6f).
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Concept QH4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Concept QH4000 in the language / languages: English, German, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 0.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info