804451
25
Zoom out
Zoom in
Previous page
1/61
Next page
48 49
ENEN
OV1200 | OV1210 OV1200 | OV1210
How to empty the water tank
1. Turn off the device.
2. Remove the tank from the unit.
3. Grasp the tank by the handle and move it gently.
4. Tilt the tank and carefully drain water out.
5. Put the tank back in the unit.
Note: Water is collected in the tank during the operation. The “Full Tank” indicator will start flashing indicating that the
water tank is full and the dehumidifier automatically stops operating.
FILTER CLEANING
Activated charcoal filter (clean approximately every two weeks)
Clean the dust from the front of the filter with a vacuum cleaner.
Place the filter in a ventilated area allowing the dispersion of harmful gases and germs. Do not expose to excessive
sunlight.
The filter is fragile. Do not squeeze it too much during vacuuming.
Do not use water to clean this filter.
REPLACING THE FILTER
We recommend to replace the filter after 6 months of using the appliance or after 1000 hours of operation. After
1000hours of operation, the indicator on the bottom of the control panel will flash yellow to indicate that the filter
needs to be replaced. After replacing (or cleaning) the filter, press and hold the air purifier control button (see page
46 - Control panel description - point 3) for approximately 7 seconds to reset the filter replacement indicator.
Warning:
1. The operating temperature of the dehumidifier is 5-32 °C. Use the appliance within this temperature range. If you
use the device outside the specified temperature range, the safety fuses will stop the operation. This is normal.
2. If the room temperature is below 5 °C, the humidity is relatively low and the dehumidifier cannot be used.
3. The built-in compressor produces heat and it slightly increases the room temperature during operation. This is
normal.
4. The dehumidifier stops operating as soon as the water tank is full.
5. The dehumidifier cannot start or stop the operation itself, in this case check the following steps:
1) Make sure both the plug and the socket are OK.
2) If it seems there is no problem, wait 10 minutes.
3) If the appliance still does not work, contact your dealer.
6. Keep a minimum distance of 15 cm between the openings of the appliance and near objects.
TROUBLE SHOOTING
Prior to sending the unit to the service centre, check following points:
Problem Possible cause Remedy
The unit does not
work
Make sure the plug is not disconnected
from the electrical outlet. Plug the power cord plug in the wall outlet.
Make sure the water tank is not full. Drain water out of the tank.
Make sure the tank is properly inserted. Put the water tank in the correct position.
Low
dehumidification
volume
Check whether the filters are dirty or not. Clean the filters as instructed.
Make sure the air openings are not
blocked.
Remove all obstructions blocking the
openings.
Loud noises during
operation
Make sure the unit is installed as
instructed. Place the unit on a stable, flat surface.
The appliance
stops operating in
the room
Check that the room temperature is not
higher than the designated operating
temperature.
As soon as the temperature drops, the
appliance will start operating automatically.
Washed laundry is
not dry
Check that the outlet of the appliance
does not aim on the laundry.
Move the laundry to the other side of the
appliance with the air inlet.
Make sure the room temperature is not
too low.
It is difficult to dry the laundry at low
temperatures.
If one of the following phenomena occurs, your appliance is OK.
Phenomenon Cause
Operation gets interrupted for
time to time The unit is defrosting.
Low dehumidification volume
If the room temperature is low, the speed of dehumidification decreases. The
unit stops if the room temperature drops below approx. 5 °C or rises above
32 °C. In automatic mode, the dehumidifier will stop if the humidity drops
below 60 %.
The humidity in the room is still
high
The room is too big. Doors or windows in the room may often get opened/
closed. The dehumidifier is used in the room along with a kerosene heater
that emits steam.
Unpleasant smell is emitted during
operation Odours come from walls, furniture or other objects.
The unit is emitting noises during
operation Circulation of the coolant can produce noises.
There is water in the water tank
after unpacking the appliance
The water in the tank was used to test the functionality of the appliance in
the factory.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Concept OV1210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Concept OV1210 in the language / languages: English, German, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 4.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info