The effective range of the transmitter incorporated in the thermostat is
approximately 50 m in open terrain. This distance may become considerably
shorter within a building, especially when a metal structure or a reinforced
concrete wall stands in the way of radio waves.
The switching sensitivity of the thermostat can be selected: ±0.2°C
(factory default setting, recommended for radiator-based heating systems) or
+0/-0.2°C (this setting is recommended for underfloor heating). This figure
means the temperature difference between the reference value and the actual
temperature measured during the switching process. For example, if the
factory default setting is 20°C on the thermostat then the device switches on
the boiler at 19.8°C or below this level and switches it off at 20.2°C or above.
(Please refer to Section 2.3 for the modification of the factory default switching
sensitivity of ±0.2°C)
The thermostat is equipped with a pump protection function, which, to
prevent the pump from sticking, switches on the boiler for a one minute period
at 12:00 p.m. every day if the pump has not been switched on in a programmed
manner for more than 24 hours (e.g. outside the heating season). See the
activation of the pump protection function in Section 2.4.
If the power supply to the receiver is interrupted for any reason (e.g. power
outage), the boiler also stops working. Shortly after the power outage the device
resumes its operation according to the program without any intervention.
THE INFORMATION SHOWN ON THE LIQUID CRYSTAL DISPLAY
OF THE THERMOSTAT INCLUDES THE FOLLOWING:
Set temperature
Timed manual control
indication
Dead battery
Sign of boiler in
operation
The days of the week
Time
Manual control indicator
Programme number
Current temperature of
the room
- 3 -
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Computherm Q7 RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Computherm Q7 RF in the language / languages: English as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info