730545
313
Zoom out
Zoom in
Previous page
1/313
Next page
311
English
The Compex Performance is designed for use in the electromagnetic
environment stipulated below. The buyer or user of the Compex
Performance must ensure it is used in this recommended environment.
- ELECTROMAGNETIC IMMUNITY
NOTE: VT is the AC supply voltage before application of the test
level.
Electromagnetic
environment - recommendations
Portable and mobile RF communication devices must only be used relative to the Compex
Performance and its wiring at a distance which is not less than the spacing recommended and
calculated using the appropriate equation for the transmitter’s frequency. Recommended
spacing
d = 1.2 P
d = 1.2 P 80 MHz to 800 MHz
d = 2.3 P 800 MHz to 2.5 GHz
Where P is the maximum output power of the transmitter in watts (W) set by the manufacturer’s
specifications and where d is the recommended spacing in metres (m). The field intensity of RF fixed
transmitters, as determined by an electromagnetic survey
a
must be less than the observance level
to be found in each frequency range
b
.
Interference may occur close to any appliance identified by the following symbol:
Electromagnetic wave propagation is modified by absorption and reflection due to buildings,
objects and persons.
In the event of abnormal operation, new measures may then be imposed, such as realignment
or movement of the Compex Performance.
b
Above the frequency amplitude from 150 kHz to 80 MHz, the field intensity must be
< 3 V/m
PERFORMANCE FR DE IT ES EN:ENGY Man FR 14/02/08 15:12 Page 311
313


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Compex Performance at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Compex Performance in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 7,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info