820626
13
Zoom out
Zoom in
Previous page
1/244
Next page
13
observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting
or relocating the device.
b Over the frequency range 150 kHz to 80 MHz, eld strengths should be less than 3 V/m.
THE DEVICE IS INTENDED FOR USE IN THE ELECTROMAGNETIC ENVIRONMENT SPECIFIED BELOW. THE CUSTOMER
OR THE USER OF THE DEVICE, SHOULD ASSURE THAT IT IS USED IN SUCH AN ENVIRONMENT.
Test Frequency
(MHz) BandaServiceaModulationaMaximum
Power (W) Distance (M) Immunity Test
Level (V/m)
385 380-390 TETRA 400. Pulse Modulationb 18Hz 1.8 0.3 27
450 430-470 GMRS 460. FRS 460. FMc +5kHz sine 20.3 28
710
704-787 LTE Band 13. 17. Pulse Modulationb
217 Hz 0.2 0.3 9745
780
810
800-960
GSM 800/900.
TETRA 800. iDEN 820.
CDMA 850. LTE.
Nand 5.
Pulse Modulationb
18 Hz 20.3 28
870
930
1720
1700-1990
GSM 1800. CDMA.
1900.
GSM 1900. DECT.
LTE Nand 1, 3.
4, 25; UTMS.
Pulse Modulationb
217 Hz 20.3 28
1845
1970
2450 2400-2570
Bluetooth WLAN.
802.11 b/g/n.
RFID 2450.
LTE Band 7.
Pulse Modulationb
217 Hz 20.3 28
5240
5100-5800 WLAN 802. 11 a/n. Pulse Modulationb
217 Hz 0.2 0.3 95500
5785
NOTE If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may
be reduced to 1m. The 1m test distance is permitted by IEC 61000-4-3.
a) For some services, only the uplink frequencies are included
b) the carrier shall be modulated using a 50% duty cycle square wave signal.
c) As an alternative to FM modulation at 18 Hz may be used because while it does not represent actual modulation, it would be worst case.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Compex Back and knee pain relief at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Compex Back and knee pain relief in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 3.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info