ComNav Vector G2 & G2B Installation & Operation Care & Maintenance
Document PN 29010078 V2.0 - 65 -
DRAFT #3 – 29 May 2009
Care & Maintenance
The Vector G2 & G2B GPS Compasses haves been designed to provide many years of
reliable service. The following care and maintenance tips will help to ensure the longevity of
your Vector.
Protection of Wires and Cabling
After installation, ensure that the system components are securely mounted and will not
shake loose due to the vibrations that can be expected in a marine vessel.
Ensure that the cable to the G2 is well secured with clamps or alternative fasteners.
Many potential problems can be avoided by ensuring that cabling and wiring do not cause
any strain on the connectors.
Periodic Checks
After the first six months of operation, a thorough examination of the entire G2 system MUST
BE UNDERTAKEN. Verify that all electrical connections, cables, clamps, mounting brackets,
and mechanical connections are secure.
An ANNUAL inspection should be undertaken thereafter.
General Precautions
A few precautions will keep the unit in prime condition:
The G2’s enclosure does not require any special maintenance. An occasional
cleaning is suggested; use a damp cloth and mild soap.
L Do not use abrasive cleaners or chemicals.
Avoid exposing the enclosure to solvents, acids, and bases – some of these may
weaken the plastic.
The G2’s enclosure is designed to be weatherproof and splash resistant, but it should
not be immersed in water for a prolonged period of time.
Environments exceeding a maximum temperature of 85°C or below a minimum
temperature of -40°C MUST BE AVOIDED.
Repair
There are no user-serviceable parts or adjustments inside the G2’s enclosure. Should the
unit become damaged in any way, return it to an authorized ComNav Dealer.
Fuse Replacement
There are no fuses used inside the G2 itself. However, it is strongly recommended that a
fuse (or circuit breaker) be installed in the G2’s Power wiring (see page 17).
L If the fuse/breaker blows, determine the cause before
replacing/resetting!!
www.busse-yachtshop.de | info@busse-yachtshop.de
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ComNav Vector G2B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ComNav Vector G2B in the language / languages: English as an attachment in your email.

The manual is 2,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info