DIP S2
Art. (6700W / 6700W/BM / 6701W / 6701W/BM ) +
Art. 6733W
DIP S1
DIP 1 DIP 2 DIP 3 DIP 4 P1 P2
P3 P4 P5 P6
ADDRESS
0 0 0 0
1 0 0 0 INT INTb
0 1 0 0 INT INTb
1 1 0 0
0 0 1 0
1 0 1 0 INT
INTb
0 1 1 0 INTb
1 1 1 0 INTb INT INT
0 0 0 1 INT INTb
1 0 0 1 INT
0 1 0 1 INT
1 1 0 1
0 0 1 1 INTb INT
1 0 1 1 INT INT INT INT INT INT
0 1 1 1
1 1 1 1 PROG
Example 1 - General intercom
on a monitor with user code 5, P3 programming = general internal call, P4 = general intercom with address 9
Example 2 - Selective intercom
on a monitor with user code 1 and intercom address 1, P3 programming = selective intercom with address 2, P4 = selective
intercom with address 3
1. Set S2 DIP switch 6 to the combination 01.
» the privacy LED flashes.
S2 DIP
1 2 3 4 5 6
0 0 0 0 0 1
S2
2. Refer to the table on page 20 and select a combination in which the intercom function (either INT or INTb) is listed for the
keys you wish to program.
E.g. 1: for P3= general internal call, set S2 DIP switches 1-2-3-4 to the combination 1000 or 0011 or 1011 (P3=INT), set S1
with address 5 in accordance with table A on page 13, go to point 3.
E.g. 1: for P4= general intercom, set S2 DIP switches 1-2-3-4 to the combination 1110 or 1011 (P4=INT), set S1 with
address 9 in accordance with table A on page 13, go to point 3.
E.g. 2: for P3= single-family intercom, set S2 DIP switches 1-2-3-4 to the combination 1000 or 0011 or 1011 (P3=INT), set
S1 with address 2 in accordance with table B on page 19, go to point 3.
E.g. 2: for P4= selective intercom, set S2 DIP switches 1-2-3-4 to the combination 1110 or 1011 (P4=INT), set S1 with
address 3 in accordance with table B on page 19, go to point 3.
3. Press and release the key to be associated with the function
» the lock-release LED lights up.
» a confirmation tone will sound.
4. To exit programming mode, set S2 DIP switches 5-6 to the combination 00
f the privacy LED switches o
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the combination 1111. Restore the user code
setting on S1, see table A on page 13.
Programming buttons for intercom call
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Comelit 8461MB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Comelit 8461MB in the language / languages: English as an attachment in your email.

The manual is 9,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info