778171
21
Zoom out
Zoom in
Previous page
1/88
Next page
21
www.combisteel.com
MAINTENANCE
SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating! For optimal
operation, clean range hood and all baffle/spacer/filter/grease tunnel/oil container regularly. Regular care will
help preserve the appearance of the range hood.
Cleaning Exterior surfaces:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive
detergent (e.g. Comet Power Scruv®, EZ-Off® oven cleaner), or steel wool/scoring pads, which will
scratch and damage the stainless steel surface. For heavier soil use liquid degrease such as “Formula
409®or “Fantastic®brand cleaner.
If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the
hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the stainless
steel cleaner. CAUTION: Do not leave on too long as this may cause damage to hood finish. Use soft
towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the
hood.
After cleaning, you may use nonabrasive stainless steel polish such as 3M® or ZEP®, to polish and buff
out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
DO NOT allow deposits to accumulate or remain on the hood.
DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause
rusting.
DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with
stainless steel for extended periods. Many of these compounds contain chemicals, which may be
harmful. Rinse with water after exposure and wipe dry with a clean cloth.
Cleaning Filters (Baffle or Aluminum Grease):
IMPORTANT: Drain oil from oil containers before oil and residue overflow!
The metal filters fitted by the factory are intended to filter out residue and grease from cooking. It need
not be replaced on a regular basis but are required to be kept clean.
Filters should be cleaned after every 30 hours of use.
Remove and clean by hand or dishwasher. Spray “Formula 409®or equivalent degreasing detergent
and leave to soak if heavily soiled. Dry filters and re-install before using hood.
Replacing Filters:
Should aluminum grease filters wear out due to age and prolonged use, please contact your local
reseller for replacement filters. (Note: Also replace damaged filter that has punctured or broken mesh,
bent or broken frame.)
Replacing the light bulb:
This range hood uses LED bulb (please refer to the actual
specification of the hood purchased): LED 3W 12V
Make sure the range hood is unplugged or turn OFF breaker.
Make sure the lights are cool to touch, carefully align the arrow on
the inner ring with the arrow on the outer ring where it says OPEN.
The inner ring will loosen and the light bulb will be available for
removal. Install a new halogen light bulb and reverse the steps.
Turn ON breaker and range hood to test for operation.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for CombiSteel 7227.0005 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of CombiSteel 7227.0005 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info