CSB200 Class B AIS
R2.0 35
Problem Possible cause Solution
Active alarm shown:
Channel A Noise
fault OR
Channel B Noise
fault
The AIS cannot
transmit because the
background noise
level is too high
Check the VHF antenna
connections.
Check the AIS
installation manual
against the specification
of your VHF antenna.
In very busy shipping
channels this alarm
may appear
temporarily. This is
normal operation for
Class B AIS.
Active alarm shown
with message not
listed here
The VHF antenna is
not connected or is
not suitable for use
with the AIS.
AIS is faulty.
Check the VHF antenna
connections.
Check the AIS
installation manual
against the specification
of your VHF antenna.
Please contact your
dealer.
CSB200 Class B AIS
R2.0 36
SERIAL DATA INTERFACE
Serial Port Input/Output
There are two serial ports, one presenting NMEA (RS422) format and the
other RS232 format. Data can be input from either or both ports.
The serial port interface(s) output:
At power-up boot-loader and main application splash text
screens including version numbers and memory status.
As a VHF Data Link Message (VDM) all incoming VHF Data
Link (VDL) data received by the CSB200.
The VHF data link own vessel (VDO) messages sent by the
CSB200 over the VHF Data Link.
AIS regional channel assignment messages (ACA) received.
These are derived from an incoming VHF Data Link message
(message 22) or a DSC message.
AIS channel management information source (ACS) messages.
Alarm messages (ALR, TXT).
The data interface will accept
Personality programming messages
Alarm acknowledgement messages (ACK)
On power up the unit will report details of the firmware versions residing
in the unit.
www.Busse-Yachtshop.de email: info@busse-yachtshop.de
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Comar CSB200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Comar CSB200 in the language / languages: English as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info