T-POWER30_T-POWER 30S
70
AL 8
NO NEG
PRESS
-In the work stage the stove
detects a pressure below the
vacuum switch setting
threshold.
-The system is stopped.
-The combustion chamber is
dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty vacuum switch.
-Check cleanness of the fume
duct and combustion
chamber.
-Check hermetic closing of the
door.
-Check closing of the
overpressure valves.
-Other reinstatement
operations must be carried out
by a service centre.
AL 9
INSUFF
DRAUGHT
-Appears when the
combustion air flow is below a
certain threshold.
-The combustion chamber is
dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty air flow meter.
-Check cleanness of the fume
duct and combustion
chamber.
-Check hermetic closing of the
door.
-Check closing of the
overpressure valves.
-Other reinstatement
operations must be carried out
by a service centre.
AL E
WATER
PRESSURE
-Occurs when the water
pressure does not come within
the values for correct
operation.
-The system is stopped.
-Occurs when the pressure
transducer on the water circuit
detects a pressure below or
above the fixed limits.
-Check the cause of the
problem, restoring the circuit
pressure by bringing it to the
normal operating value.
AL b
AUG TRIAC
ERROR
-Occurs when the gearmotor
works continuously and for
more than 60 sec.
-The system is stopped.
-The controller detects a faulty
gearmotor control relay
(contacts stuck).
-Reinstatement operations
must be carried out by a
service centre.
AL c
WATER
PROBE
-Occurs in case of a water
temperature probe fault.
-The shutdown procedure is
activated.
-Faulty probe
-The probe is disconnected
from the board.
-Reinstatement operations
must be carried out by a
service centre.
AL d
HOT
WATER
-Occurs when the water
temperature has exceeded the
fixed limits.
-The system is stopped.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Check the cause of the
problem, restoring the
temperature by bringing it to
the normal operating value.
WAITING
COOL
-Occurs on relighting the stove
immediately after having shut
it down.
-Reset attempt in shutdown
stage with stove hot in cooling
stage.
-Alarm reset is possible only
after shutdown.
AIR FLOW
METER
FAILURE
-Occurs when the air flow
meter is disconnected.
-The controller does not detect
the quantity of combustion air
and does not shut down the
stove; it only excludes the air
flow meter functions.
-Reinstatement operations
must be carried out by a
service centre.
FROST RISK
-Occurs when the water
temperature falls below a
certain value.
-The stove control detects the
water temperature below 6°C
and displays a message.
-The pump starts in order to
move the water inside the
heating circuit.
- Monitor the water
temperature so that it does not
fall below 0°C.
SERVICE
DUE
-Occurs when the stove has
exceeded 1800 hours of
operation since the previous
servicing.
-Extraordinary maintenance
notice.
- Cleaning - extraordinary
maintenance and
reinstatement operations must
be carried out by a service
centre.
The Manufacturer reserves the ri
ght to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola TERMO POWER 30S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola TERMO POWER 30S in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info