669018
50
Zoom out
Zoom in
Previous page
1/175
Next page
T-POWER30_T-POWER 30S
50
The request for these accessories must go with the supplementary electronic board model ‘I055’ for management of
commands with possible upgrading of software to be placed on the control main board.
After completing the DHW connection it is necessary to access the technical menu of the control and select the type
of circuit; every specific DHW function set: DHW EXCHANGER, BOILER or DHW BOILER appears on the display at
the moment of heating-DHW switchover with one of the messages given below and remains until the end of the
DHW request by the thermostat or flow switch :
Hydraulic diagram - heating pellet stove with sanitary pump
Heating pellet stove
Thermostat
T
>
85°C
Pellet heating
chamber - 2011
Pt=20-25 kW
Heating DELIVERY
male 1“
Water supply F1/2”
Pmax 2 bar
KEY
Arrangement
PLUMBING CONNECTIONS on back of
stove
Heating RETURN
male 1“
Heating DELIVERY
male 3/4“
Heating RETURN
male 3/4“
OVERPRESSURE WATER
DISCHARGE F1/2”
Int. volume 23.5 l
t
.
Drain cock
Pressure sensor / Pressure gauge
Non-return valve
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Circuit / heating chamber air ven
Valves to be included in system
during installation – not supplied
with the unit
Safety valve P max 3 bar
Safety sensor T > 85°C
Water temperature sensor
Circuit pressure sensor
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola TERMO POWER 30S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola TERMO POWER 30S in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 9,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info