669006
46
Zoom out
Zoom in
Previous page
1/159
Next page
TERMO-PERLA LUX
46
2.10 Emergency
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using fire-extinguishers.
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
Int. volume 18.5 l.
Hydraulic diagram - heating pellet stove ref. COLA 10-14kW 06-2010
Heating pellet stove
Thermostat
T
>
85°C
Pellet heating
chamber – 2010
Pt=10
-
14 kW
Water supply F1/2 “
Pmax 2 bar
KEY
Arrangement
PLUMBING CONNECTIONS on back of stove
Heating DELIVERY
male 3/4“
Heating RETURN
male
3/4“
OVERPRESSURE WATER
DISCHARGE F1/2”
Drain cock
Pressure sensor / Pressure gauge
Non-return valve
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Circuit / heating chamber air ven
Valves to be included in system during
installation – not supplied with the unit
Safety valve P max 3 bar
Safety sensor T > 85°C
Water temperature sensor
Circuit pressure sensor
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola TERMO-PERLA LUX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola TERMO-PERLA LUX in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 6,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info