669026
8
Zoom out
Zoom in
Previous page
1/14
Next page
7
Mini Johanna
Roof
slope
(α)
(α) (α)
(α)
Distance A H
15°
1.00 m
30°
1.30 m
45°
2.00 m
60°
More than 1.85 m
2.60 m
2.3 Connection to the flue
The MINI JOHANNA stove must be connected to the flue by means of the collar on the hotplate, using flue pipes that
are readily available on the market. Connection to the flue must be made using strong and stable pipes (recommended
min. thickness 1.2-2 mm). The flue pipe must possibly be straight, to avoid pressure losses, and towards the flue. The
ends of the flue pipe must be tight.
To ensure regular operation, the flue draught with stove operating must be between 10 and 14 Pa.
For optimum stove efficiency, a draught control or
damper must be fitted in the flue pipe or chimney.
Every unit must eliminate the fumes through its own flue; never use the same flue for several units.
2.4 Room ventilation
The air necessary for combustion, i.e. up to 25 m³ every hour, must be ensured in rooms where stoves with natural flue
draught are installed. The air change must occur through several fixed openings to the outside, whose cross section
must comply with the current local regulations. Such openings must be protected with grilles and must never be
obstructed.
If the air is insufficient, even the operation of an extractor hood in the room or exhaust fans can negatively affect stove
operation.
2.5 Advice on flues and connections
Flues must be made from suitable materials and perfectly insulated, with characteristics that prevent temperature
decreases.
The inner walls must be perfectly smooth without any narrowing or protrusions along the entire length, so as not to
create friction or vortices in the smoke which could cause a considerable reduction in draught.
Any cleaning and inspection doors must be perfectly closed during operation.
The flue outlets must be 0.5 m higher than any obstacles located less than 10 m away and must end with chimney
caps or cowls having a useful outlet cross section of at least double that of the flue.
The following two figures give the data regarding the distances and positioning of chimney caps in conformity with the
provisions of UNI 10683/98.
obstacle
Less than 5 m
Min 0.5m
Min 0.5m
Approx. 0.5m
Min 0.5m
The chimney mouth must be at least
0.5m from the top of any obstacle
within a range of 10
m
fig. 3 Chimney cap positioning and distances
UNI 10683/98 tables
Roof slope
(α)
(α) (α)
(α)
Distance B H
15°
0.50 m
30°
0.50 m
45°
0.50 m
60°
Less than 1.85 m
0.50 m
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cola Mini Johanna at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cola Mini Johanna in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info