635854
7
Zoom out
Zoom in
Previous page
1/12
Next page
After connection, open the valve of cold water supply to the EWH and the hot water tap
on the mixer to allow air to escape from the water heater. When the EWH is finally filled, cold
water will continuously run from the mixer tap.
When the EWH is connected in places, where there is no water supply system, water can
be supplied to the EWH from an auxiliary tank located at least at 5 meters from the top of the
EWH, or by using a pumping plant.
Note: to facilitate maintenance of the EWH during operation it is recommended to install
a drain valve as shown in Fig. 1 (for models that are not equipped with a drain valve (beyond the
scope of supply)).
If pressure in a water supply system exceeds 0.6 MPa, it is necessary to install at the inlet
in front of the EWH a reducing valve (beyond the scope of supply) to reduce water pressure to
its normal value.
6.3. CONNECTION TO A POWER SUPPLY NETWORK
WARNING! Before turning on power supply, make sure that the EWH is filled with
water. The EWH is equipped with a standard power cord with a plug and PCD (optionally). An
outlet should have an earth terminal and be located in a place, protected against moisture.
The outlet and its leads should be designed for nominal power of 2000W, at the least.
Put a plug into the outlet (if the EWH is optionally equipped with PCD, press a button on PCD).
7. OPERATION AND MAINTENANCE
7.1. Models with mechanical control (Fig. 3)
The models with mechanical control on the EWH control panel have power selection
keys (I and II) with built-in indicating lamps. Actuated key I corresponds to power of 1.3 kW,
actuated both keys correspond to power of 2 kW. You may select one heating power or the other
on the basis of your requirements for hot water or depending on the season. When the EWH is in
operation, the Consumer may regulate the heating temperature with the regulator on the control
panel. Turning the regulator counter-clockwise until it stops disconnects the EWH from the
network, while turning the regulator clockwise gradually increases the temperature up to +75°С.
7.2. Models with electronic control by version 1 (Fig. 5)
In the models equipped with electronic panel by version 1 with a digital display, the
water heater can be turned on or off with the left-hand button on the control panel, "ON/OFF," in
which case the display shows the preset heating temperature. In 2.5 seconds thereafter the
display shows the current temperature of the water in the EWH. The heating power can be
selected with the middle button "Power selector" on the control panel. The 2 kW mode is
accompanied by indication of the pilot lamp L2, and the 1.3 kW mode is accompanied by
indication of the pilot lamp L3. When the EWH is in operation, the Consumer can regulate the
heating temperature with three soft keys, while the modes can be controlled by information on
the display and indication of three pilot lamps. To select the heating temperature, you have to
press several times the right-hand button "Temp. Selector" on the control panel. Discreteness of
temperature changes - 5°С.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cointra Thermex ID at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cointra Thermex ID in the language / languages: English as an attachment in your email.

The manual is 0,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cointra Thermex ID

Cointra Thermex ID User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info