11
any gas smell before ignition! Make sure it is screwed all
the way on. For European models, ensure that the black
rubber washer is securely in the gas input connection.
6. Attach your water output apparatus to the fitting marked
“Water Outlet”. Do not over tighten! If installing in an
existing water system, connect the hot water line directly
to the ½” NPT/BSP fitting.
7. Install two “D” cell batteries in the compartment on the
bottom left of the heater. Check that batteries are facing
the correct direction.
8. Use the top tab on the unit to suspend from a screw
adequate to holding 30 pounds/13 KG. Place at a
comfortable height without putting stress on the gas
hose. If the unit is to be permanently mounted, use
screws to attach the bottom tab firmly.
9. Attach gas regulator with hose to the LP tank. Use hand
pressure only on the plastic connector. LEAVE GAS
TANK VALVE IN THE “OFF” POSITION”.