538262
11
Zoom out
Zoom in
Previous page
1/15
Next page
17
NothingComes Close to a Cobra
16
OperatingIndicators
Operation
OperatingIndicators
Operation
Operating Indicators
Indicators at the Output End of the unit show the unit’s
power status and alarms for conditions that could cause
it to shut down.
Power on The Voltage Input
and Power Output indicators
automatically toggle between input
and output values at three-second
intervals. The three LEDs indicate
the mode the meter is in and the
three digits indicate the voltage
or power value.
Current Overload Protection
If the inverter is overloaded,
it will shut down to protect itself.
The meter will flash as shown to
indicate Overload Protect.
To restore normal operation,
disconnect the excessive load
and turn the unit Off and On
again using the Power Button.
Short Circuit Protection If the
AC output of the inverter is short-
circuited for one second or more,
it will shut down to protect itself.
The meter will flash as shown to
indicate Short Circuit Protect and
an alarm will sound.
To restore normal operation,
disconnect the short circuit and
turn the unit Off and On again
using the Power Button.
Low Voltage Protection – If the
DC input voltage drops below
the alarm threshold of 11.3V the
meter will flash as shown to
indicate Low Voltage Protection,
but the unit will continue to
operate. If the input voltage drops
to 10.0V or less, the inverter will
shut down to protect itself, the
meter will continue to flash as
shown, and an alarm will sound.
To restore normal operation, return
the DC input voltage to at least
12V. The inverter will automatically
return to normal operation.
High Voltage Protection – If the
DC input voltage rises above 15.0V,
the inverter will shut down to protect
itself, the meter will flash as shown
to indicate Over Voltage Protection,
and an alarm will sound.
To restore normal operation, return
the DC input voltage to less than
15V. The inverter will automatically
return to normal operation.
HighVoltage
OverCurrent
ShortCircuit
LowVoltage
OutputWatts
10274_CPI1000_vD:CPI1550-Eng 6/27/11 12:08 PM Page 16
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cobra CPI 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cobra CPI 1000 in the language / languages: English as an attachment in your email.

The manual is 1,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info