If you do not want to have the LEDs on, use the block function. It will take 10 minutes, after activating the block function, to switch off the
led
5.6 OPEN WINDOW
The device is provided with a protection against loss of temperature caused by open window, air conditioners, or any other circumstance
that may prevent the radiator from raising the room temperature. This mode activates when the temperature decreases 3ºC in 5 minutes.
At this stage, this mode stays until this decreasing tendency disappears.
6.RECOMMENDATIONS OF USE
The Climastar range of heating products needs no maintenance. Only certain preventive measures may be necessary:
Do not cover the air exits. Do not place clothing over them.
Keep floors clean to avoid staining on the wall.
At the start of each heating season, vacuum the interior of the equipment. After being switched off for some time, dust may accumulate
on the element.
Do not place the equipment under a ventilation grill or near any location that may generate a draught.
Install the equipment so that nothing prevents the circulation of air generated (furniture, curtains, etc). Otherwise, a loss of
temperature control or performance may be found.
To prevent loss of heat and therefore wasting electricity, if possible improve insulation of the windows with draught excluders, double
glazing or thermal breaks.
The DUAL KHERR can be cleaned with a damp cloth, alcohol or even nitric acid (for difficult stains). Due to its durability, it will not
be degraded by the use of any type of substance (Standards EN 99 and EN 202). Also, thanks to its composition, direct sunlight can
shine directly on the equipment without altering its appearance (Standard EN 51094).
The equipment cover can be cleaned with a damp cloth.
7.TECHNICAL DATA
Measures & Weight
Description: OPTIPLUS 1600
Measures: 320x500x140 (mm)
Weight: 9,8 kg.
Technical Characteristics
Voltage: 230 V
Frequency: 50 Hz
Plug: Bipolar 10-15A/250 VAC
Safety thermostat: Automatic – Rated temp. 90 ± 0,5º - Reset temp. 65º ± 1
Electronic thermostat: Temperature Range 17 - 24 ºC
Type of protection: Class II IP 24
Materials
Back cover:
High quality steel
Front:
Dual
Kherr
8.FAQS
PROBLEM PROBABLE CAUSE SOLUTION
The room does not reach
the desired temperature
Incorrect setting of the set
temperature Check the set temperature on the display to verify it is the desired
temperature.
Improper sizing The power is not the adequate for the place in which it has been
installed.
Input and output grids are
obstructed Do not place anything on top of the radiator and do not install it
inside a cavity wall.
Set temperature below room
temperature Rise the radiator’s set temperature until it is 1 degree above the room
temperature
The radiator does not
operate
Check that the automatic control is
not down. If it is down put it up. Check that the automatic control is not down. If it is down put it up.
Switch it off Make sure the installation is correct and that there are independent
lines for the heating system with a 2.5 mm2 cable gauge and a
maximum power of 3500 w.
Program is OFF Check that the set program is the chosen one or set the one you
desire.
Blocked buttons No response from operating
buttons Press buttons ON and TIMER for 3 seconds.
9.GUARANTEE
WARNING FOR THE CORRECT DISPOSAL OF THE PRODUCT AS ESTABLISHED BY EUROPEAN DIRECTIVE 2002/96/EC
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Climastar Optiplus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Climastar Optiplus in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 3.54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info