4.
LED display
Shows the set temperature while on cool, heat or auto mode. While on DRY and FAN
modes, it shows the room temperature. Shows Error codes:
E0-EEPROM error.
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (on some models).
E4-Display panel communication error.
EC-Refrigerant leakage detection
malfunction(on some models).
Shows protection code:
P1-Bottom tray is full--Connect the drain hose and drain the collected water away.
If protection repeats, call for service.
NOTE: When one of the above malfunctions occurs, turn off the unit, and check for any
obstructions. Restart the unit, if the malfunction is still present, turn off the unit and
unplug the power cord. Contact the manufacturer or its service agents or a similar
qualified person for service.
Operation Method
Cooling mode
When the A/C enters cooling mode automatically or cooling mode is selected after
power
ON, the cooling indicator lamp lights up.
Press Up/Down key to adjust setting temperature (17~30).
Press FAN SPEED on the remote controller to choose High/Low speed.
Fan mode
When pressing mode key or choosing Fan mode by pressing the remote controller,
the wind
indicator lamp lights up.
Press FAN SPEED on the remote controller to choose High/Low speed.
Temperature can’t be set.
Do not put the duct to window
Dehumidifying mode
When pressing mode key or choosing dehumidifying mode by pressing the remote
controller, the indicator lamp lights up.
After choosing this mode, operation state is determined by environmental
temperature:
when environmental temperature is higher than 17, the operation state is the same as that
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Climadiff CLIMA5K1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Climadiff CLIMA5K1 in the language / languages: English, French as an attachment in your email.

The manual is 2,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info