As soon as a warning is displayed, the steam function can no longer be used!
Warnings can be not deleted; press the light push-button to ignore a warning. If the functional state does not change, the
warning is displayed again when the respective function is selected again.
After pressing the light push-buttom at warning A19, an automatic drain process of steam generator will be starting.
Error messages can be eliminated without loss of data with a mains reset (switching the FI switch off and on again after 10
seconds).
Warning Type of Malfunction / Cause Possible Cause Possible Clearance
A13 - Filling failure at the start of
steaming in the first 3
minutes, i.e. lower and
upper water levels not
reached (e.g. during initial
start-up)
- Solenoid valve error
- Level sensor error
(Symptom: Water emerges
from the drain pipe during
steam operation)
- Steam module error
- Ball valve before steam
generator closed
- Filter in connection bracket
of steam generator clogged
- Insufficient on-site water
supply
- Solenoid valve defective or
disconnected
- Level sensor defective or
disconnected
- Steam module defective or
no voltage supply
- Open ball valve
- Clean filter in connection
bracket
- Ensure sufficient water
supply
- Replace solenoid valve
membrane or connect
cable (cable on steam
module with “Fill” marking)
- Replace level sensor or
connect cable (cable on
steam module with “Level”
marking)
- Replace steam module or
connect cable (cable on
steam module with “Mains
230V” marking)
A14 - Filling at the start of
steaming in the first 3
minutes insufficient, i.e.
lower water level reached,
but not upper water level
- Ball valve before steam
generator closed
- Filter in connection bracket
of steam generator clogged
- Insufficient on-site water
supply
- Solenoid valve defective or
disconnected
- Open ball valve
- Clean filter in connection
bracket
- Ensure sufficient water
supply
- Replace solenoid valve
membrane or connect
cable (cable on steam
module with “Fill” marking)
A16 - Maximum cabin
temperature of 55°C
exceeded
- Safety cut-out when
maximum allowed cabin
temperature exceeded
- Allow cabin to cool down
A17 - Drain process of steam
generator defective
- Generator calcified, i.e. drain
outlet and / or pipe clogged
- Remove generator and
clean generator including
drain pipe
A18 - Measured values from
cabin temperature sensor
out of tolerance
- Cabin temperature sensor
defective or disconnected
- Replace or connect cabin
temperature sensor
A19 - Steam generator is filled up
or is filled particular when
starting
- Solenoid valve defective
(untight)
- Clean solenoid valve
membrane or replace it
K IV STEAM PLUS CONTROL
Italiano
83


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cleopatra Wellspring 130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cleopatra Wellspring 130 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 28,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info