Type of Malfunction / Cause Possible Cause Possible Clearance
x Air system does not function x Check you have an electricity supply?
Malfunction in electrical mains
Are the plug connections to the
control correctly seated?
x Control does not react
x Control defective
x Control element defective
x Blower defective
Call electrician
Pull and reinsert plug
x Reconfigure Poolmaster
x Replace control
x Replace control element
x Replace blower
x Hydro system function insufficient
x Hydro system does not function
x Filter at intake socket is blocked
x Nozzle dirty
x Is voltage applied?
Malfunction in electrical mains
Are the plug connections to the
control correctly seated?
x Is the water level high enough?
x Water level sensor does not react
x Control does not react
x Control defective
x Control element defective
x Hydraulic pump defective
x Remove cover at intake socket and
clean filter (see service)
x Clean nozzle (see service)
Call electrician
Pull and reinsert plug
x Continue to fill tub
x Adjust sensor
x Replace sensor
x Reconfigure Poolmaster
x Replace control
x Replace control element
x Replace hydraulic pump
x System switches itself on without an
obvious reason
x Automatic cleaning function of the air
nozzles
x Has the room temperature changed
(e.g. floor heating underneath the
whirlpool)
x Has the humidity in the room changed
(e.g. use of a shower in the same room)
x Were cables, water pipes or other
electrically conductive materials laid in
the area of the water level sensor?
x Is/was cleaning work performed near
the tub? (e.g. moist cleaning cloth near
the water level sensors)
x Okay
x Readjust sensitivity of the water level
sensor
x Readjust sensitivity of the water level
sensor
x Reposition cables, water pipes or similar
x Remove objects from the tub
x Water nozzle x Nozzle dirty
x Nozzle head not adjustable
is seized
is loose
x Clean nozzle (see service)
Reposition O-ring behind head
Replace O-ring behind head
Leakage:
x air
x Water underneath the tub
x Air hose loosened on:
Blower
Air distributor
Air nozzle
x Hydro hose loose on:
Pump
Hydro nozzles
x Drain/overflow defective?
x Seals on nozzles leaking?
x Acrylic material damaged?
x Tub inflow connection leaking?
x Tighten hose clamp / disconnect and
reconnect hose
x Retighten hose clamp
x Replace seals
x Replace seals
x Repair acrylic material with repair sets
x Replace seals
x Underwater lighting does not switch on x Is the water level high enough?
x Lighting element defective?
x Is voltage applied?
Malfunction in electrical mains
Are the plug connections to the
control correctly seated?
x Water level sensor does not react
x Continue to fill tub
x Replace lighting element
Call electrician
Pull and reinsert plug
x Adjust sensor
x Replace sensor
Disinfektion:
x Can not be started
x Switches off during the process
x Is the water level high enough?
x Is the water level high enough?
x Is the disinfectant container adequately
filled?
x Continue to fill tub
x Continue to fill tub
x Replenish container with disinfectant.