6 Product specications
6.1 Technical data
Steam capacity in kg/h 5 8 15 23 32 45 65
Capacity range in kg/h 1...5 1.6...8 3...15 4,6...23 6,4...32 9...45 13...65
Nominal power in kW 3,8 6,0 11,3 17,3 24,0 33,8 48,8
Heating voltage 230V/1~/50..60Hz *
Unit model 522 822
Nominal current in A 16,3 26,1
Steam cylinder type ** 522A 822A
Heating voltage 400V/2~/50..60Hz *
Unit model 524 824
Nominal current in A 9,4 15,0
Steam cylinder type ** 524A 824A
Heating voltage 230V/3~/50..60Hz *
Unit model 532 832 1532 2362 3262
Nominal current in A 9,4 15,1 28,2 43,3 60,2
Steam cylinder type ** 532A 832A 1532A 2362A 3262A
Heating voltage 400V/3~/50..60Hz *
Unit model 534 834 1534 2364 3264 4564 6564
Nominal current in A 5,4 8,7 16,2 24,9 34,6 48,7 70,4
Steam cylinder type ** 534A 834A 1534A 2364A 3264A 4564A 6564A
Steam cylinder type *** 534A-L 834A-L 1534A-L 2364A-L 3264A-L 4564A-L ---
Control voltage 230 V/1~/50..60 Hz
Operating conditions
Admissible water pressure 1...10 bar
Water quality Untreated drinking water with a conductivity of 125...1250 µS/cm
Admissible water temperature 1...40 °C
Admissible ambient temperature 1...40 °C
Admissible ambient humidity max. 75 %rF (non condensing)
Admissible air pressure in the steam bath cabin -0.8 kPa...1.5 kPa
Type of protection IP21
Conformity CE, VDE, GOST
Dimensions/Weights
Width in mm 428 428 508 508 563 563 563
Height in mm 575 575 620 620 640 640 640
Depth in mm 255
255 345 345 354 354 354
Net weight in kg 12 19 28 30
Operating weight in kg 17 29 65 67
Water supply connector G 3/4" (male thread)
Water drain connector ø 31 mm (outside diameter)
Steam connector 1x ø 22 1x ø 35 2x ø 35
Options
Cable gland 1x CG
Steam hose connector with condensate trap 1x CT22 1x CT35 2x CT35
Internal control voltage supply 1x S-CVI 1x M-CVI 1x L-CVI
@Link Cleo Premium Pro @Link Cleo Premium Pro
Accessories
Filter valve 1x Z261
Cleo Premium Pro Remote Terminal
RP
Cleo Premium Pro Touch Screen Panel
TSP
Temperature sensor KTY KTY
Steam distributor 1xW22 1xW35 2xW35
Fragrance pump 1xFP 240V
T-piece for fragrance injection 1xTSD22 1xTSD35 2xTSD35
Steam hose / meter 1xDS22 1xDS35 2xDS35
Condensate hose / meter KS10
Condensate drain 1xCD22 1xCD35 2xCD35
EcoTherm insulation hose 1xECT22 1xECT60 2xECT60
50-210VA transformer for 4x50W lamps TRL
* Other heating voltages on request
**
Steam cylinder for water conductivity from 125 to 1250 µS/cm (standard version)
*** Steam cylinder for low water conductivity from 80 to 125 µS/cm
46


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cleopatra Cleo Premium Pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cleopatra Cleo Premium Pro in the language / languages: English as an attachment in your email.

The manual is 7,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info