10 Productspecications
10.1 Technicaldata
Steam capacity in kg/h 5 8 15 23 32 45 65
Capacity range in kg/h 1...5 1.6...8 3...15 4,6...23 6,4...32 9...45 13...65
Nominal power in kW 3,8 6,0 11,3 17,3 24,0 33,8 48,8
Heating voltage 230V/1~/50..60Hz *
Unit model 522 822
Nominal current in A 16,3 26,1
Steam cylinder type ** 522A 822A
Heating voltage 400V/2~/50..60Hz *
Unit model 524 824
Nominal current in A 9,4 15,0
Steam cylinder type ** 524A 824A
Heating voltage 230V/3~/50..60Hz *
Unit model 532 832 1532 2362 3262
Nominal current in A 9,4 15,1 28,2 43,3 60,2
Steam cylinder type ** 532A 832A 1532A 2362A 3262A
Heating voltage 400V/3~/50..60Hz *
Unit model 534 834 1534 2364 3264 4564 6564
Nominal current in A 5,4 8,7 16,2 24,9 34,6 48,7 70,4
Steam cylinder type ** 534A 834A 1534A 2364A 3264A 4564A 6564A
Steam cylinder type *** 534A-L 834A-L 1534A-L 2364A-L 3264A-L 4564A-L ---
Control voltage 1 x 230V / 50-60 Hz
Operating conditions
Admissible water pressure 1...10 bar
Water quality Untreated drinking water with a conductivity of 125...1250 µS/cm
Admissible water temperature 1...40 °C
Admissible ambient temperature 1...40 °C
Admissible ambient humidity max. 75% rh (non condensing)
Admissible duct air pressure -0.8 kPa...1.5 kPa; overpressure kit (option) up to 10.0 kPa
Type of protection IP 20
Conformity CE, VDE, GOST
Dimensions/Weights
Housing (WxHxD) in mm 377x612x279 1 1 1
492x670x351 1 1 1 1
Water supply connector G 3/4" (outside thread)
Water drain connector ø 30 mm
Steam connector 1 x ø 22 mm 1 x ø 35 mm 2 x ø 35 mm
Net weight in kg 19 19 28 28 28 28
Operating weight in kg 24 30 65 65 65 65
Options
Cable gland 1xCG
Overpressure set 1xOPS
Remote operating and fault indication 1xRFI
Steam hose connector with condensate trap 1xCT22 1xCT35 2xCT35
Internal control voltage supply 1xS-CVI 1xM-CVI 1xL-CVI
Transformer (400 V/230 V) 1xM-Trafo 1xL-Trafo
Terminals heating voltage 1xS-THV 1xM-THV 1xL-THV
SC pump 1xSC
24 VDC power supply 1x24VDC
Accessories
Filter valve Z261
Steam distribution pipe 1x DV41-... 1x DV71-... 2x DV71-...
Steam distribution system MultiPipe ––– 1xSystem 1 1xSystem 2
Fan unit 1xFAN4 N S W 1xFAN4 N M W 1xFAN4 N L W
Steam hose / meter 1xDS22 1xDS35 2xDS35
EcoTherm insulation hose 1xECT22 1xECT60 2xECT60
Condensate hose / meter KS10
Duct humidistat 1xHBC
Room humidistat 1xHSC
All-waether protective housing Layout according to the separate data sheet
* Other heating voltages on request
** Steam cylinder for water conductivity from 125 to 1250 µS/cm (standard version)
***
Steam cylinder for low water conductivity from 80 to 125 µS/cm
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cleopatra Cleo Eco Pro Steam generator at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cleopatra Cleo Eco Pro Steam generator in the language / languages: English as an attachment in your email.

The manual is 10,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info