CONVERGE PRO 840T
Audio Performance
Conditions: Unless otherwise specified, all •
measurements are performed with a 20 Hz to 22 kHz
BW limit (no weighting)
Frequency Response: 20 Hz to 22 kHz ±1dB•
Noise (EIN): -126 dBu, 20 kHz BW, max gain,•
Rs=150Ω•
THD+N: <0.02%•
Dynamic Range: >100 dB (non A-weighted)•
Crosstalk <-91 dB re 20 dBu @ 20 kHz channel to •
channel
Auto Mixer Features
Number of Open Microphones (NOM)•
PA Adaptive Mode•
First Mic Priority Mode•
Last Mic Mode•
Maximum # of Mics Mode•
Ambient Level•
Gate Threshold Adjust•
Off Attenuation Adjust•
Hold Time•
Decay Rate•
Matrix Mixing Features
29x30 matrix•
8 analog in/out•
1 speaker out (amplified)•
12 expansion bus in/out•
4 assignable processing blocks in/out•
4 assignable fader blocks in/out•
1 telco in/out•
Assignable Processing Blocks
Filters•
All pass »
Low pass »
High pass »
Low shelving »
High shelving »
Parametric EQ »
Notch »
CD Horn »
Crossovers•
Bessel »
Butterworth »
Linkwitz-Riley »
Compressor•
Delay; adjustable up to 250 ms•
Assignable Fader Blocks
Gain/Mute•
Microphone Input Configuration
Input Gain Adjust•
Mic or Line Level•
Phantom Power on/off•
Echo Cancellation on/off•
Noise Cancellation on/off•
Filters•
All Pass »
Low Pass »
High Pass »
Notch »
PEQ »
Mute on/off•
Chairman Override on/off•
AGC on/off•
Automatic Level Control on/off•
Auto Gate/Manual gate•
Adaptive Ambient on/off•
Pre AEC channel•
Mic/Line Inputs 1-4
Push-on mini-terminal block, balanced, bridging•
Impedance:<10KΩ•
Nominal Level: adjustable -56 dBu to 0 dBu (7 dB step •
coarse gain adjustment)
Maximum Level: -65 dBu to +20 dBu•
Echo Cancellation: 130 ms tail time (works with 12 dB •
of room gain)
Noise Cancellation: 6–15 dB attenuation•
Phantom Power: 24 V, selectable•
Line Inputs 5-8
Push-on mini-terminal block, balanced, bridging•
Impedance:<10KΩ•
Nominal Level: 0 dBu•
Maximum Level: 20 dBu•
Outputs 1-8
Push-on mini-terminal block, balanced•
Impedance:<50Ω•
Nominal Level: 0 dBu•
Maximum Level: 20 dBu•
Amplifier Output
Binding Post Connection•
10Watts@4ΩImpedance•
THD + Noise: < 0.5%•
Telco Line
RJ-11•
POTS (plain old telephone service) or analog extension •
from a PBX
A-lead supervision provided•
Telco Set
RJ-11•
POTS (plain old telephone service) or analog extension •
from a PBX
A-lead supervision provided•
Telephone Audio Performance
Conditions: Unless otherwise specified, all •
measurements are performed with Transmit Limiter and
Receive ALC disabled
Frequency Response: 250Hz to 3.3 kHz ±1dB•
THD+N: <0.3% re-max level 250 Hz to 3.3 kHz•
SNR: > 62 dB re-max level•
Telco Line Echo Cancellation
Tail Time: 31 ms•
Null: 55 dB nominal•
Telephone Noise Cancellation
Noise Cancellation 6-15 dB attenuation•
Expansion Bus In/Out
Proprietary Network•
RJ-45 (2), 1.9 Mbps•
CAT-5 twisted-pair cable, 200’ maximum cable length•
318


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ClearOne PRO 8i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ClearOne PRO 8i in the language / languages: English as an attachment in your email.

The manual is 10,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info