735421
6
Zoom out
Zoom in
Previous page
1/11
Next page
6
Press the Power Button to activate the humidifier. The machine is now operating in manual mode.
It will release cool mist on a constant basis with the mist intensity level automatically set to
medium. The jet at the top of the machine can be rotated to blow mist in different directions. You
may also lift the jet from the water tank, adjust the positions and reinsert them back into the top
of the water tank. The output jets should not be set to spray directly onto people, electrical devices
or any obstructions. It is best to direct the jet into the open air.
The Min/Max Button changes the mist level (low, medium, high). This change is displayed on the
LCD screen by the bars that grow in size.
Pressing the Humidity Button activates automatic mode (when the LCD display starts to blink the
word “HUMID”). You can select the desired humidity level by pressing this button repeatedly until
the required humidity level is displayed (from 45% to 90% in increments of 5%). Once you select
your desired humidity level, simply stop pressing the button and your humidity level will be set.
Wait another 5 seconds and the numeric value on the LCD display will switch to the current
humidity level as measured by the built-in Hygrostat. When the humidity level in the room reaches
the set humidity level, the machine will go into automatic sleep state and stop producing mist.
When the room’s actual humidity level drops below your set humidity level about 1-5%, then the
machine will start producing mist again.
You can deactivate automatic mode very easily by pressing the humidity button until you reach
90% RH. Press the button one more time and you will now be in manual mode. You will know that
you are in manual mode because the blinking “HUMID” icon disappears.
Pressing the Ion Button will activate the negative ion generator and start sending healthy
negative ions into the air. It will be represented by the tree icon displayed on the LCD screen.
The Heating Button activates the warm mist feature and is shown on the LCD display with three
wavy vertical lines. The water is heated in the basin just prior to misting. Please do not place your
hand over the jet when the warm mist function is activated. The warm mist may raise the
temperature of the room and may affect the values shown on the display.
The Timer Button sets the timer. The timer function determines how many hours the humidifier
will operate. You can set the timer simply by pressing it once for each hour that you would like to
run the unit. Many people set the timer for 8-9 hours (during their sleep) but it can be set from 1
hour to 12 hours. As time passes, the time value decreases until it goes to 00:00 and the machine
shuts off.
If the humidifier should run out of water, you will hear a beeping sound before the machine will
automatically shut off. The LCD screen will display the Empty Water Tank icon.
The bright LCD display is designed to automatically dim after 30 seconds of pressing any of the
LCD panel buttons. The power light is also dimmed because the water tank is tinted. The result is a
soft blue glow. The light levels are bright enough to indicate that the machine is operating, yet low
enough to ensure a restful sleep in near darkness.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Clean Air Optima CA-606 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Clean Air Optima CA-606 in the language / languages: English as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Clean Air Optima CA-606

Clean Air Optima CA-606 User Manual - German - 9 pages

Clean Air Optima CA-606 User Manual - Dutch - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info