735427
9
Zoom out
Zoom in
Previous page
1/42
Next page
9
Cleaning and Maintenance
You can ensure many years of trouble free operation of your Clean Air Optima CA-603 humidifier
by following a few simple maintenance procedures. If your water is hard, containing high
concentrations of calcium and other minerals, then over a period of time white dust will start to
deposit on the various surfaces in the room. A white, film-like substance will also start to develop
in the water basin, on the transducer and on the inner surface of the water tank. This white film
will impede the proper function of the transducer and the operation of the machine.
We recommend the following
1. If your water is very hard, we recommend that you boil it first, allow it to cool completely
before use in the humidifier. The boiling will reduce the mineral concentration in the water.
The other option is to use distilled water if your mineral level is still too high.
2. If you are using the machine on a daily basis, clean the transducer, water tank and basin
once a week.
3. When the water tank needs a refill, empty the remaining water from the tank and fill it with
fresh water.
4. Clean the whole machine and make sure to keep all the parts completely dry when the
machine is not in use.
How to clean the transducer
1. Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5 minutes.
2. Using a small brush, cotton swab or tooth brush, gently clean the mineral film from the
surface of the transducer.
3. Rinse the transducer with clean water.
4. Never use sharp or solid objects for cleaning the transducer.
How to clean the water basin
1. Clean the water basin with a soft damp cloth. If there is excess film on the surfaces, then
soak the cloth with vinegar and repeat the process.
2. If there is a film in any of the depressions along the basin, drop a bit of vinegar into
depression and clean it out with a brush.
3. Rinse the basin with clean water.
How to clean the White Dust & Anti-Microbial Filter
1. Remove the filter from the water tank.
2. Put some white vinegar into a glass. Soak the filter in the vinegar for about 10 minutes.
3. Remove the filter from the glass and shake it several times.
4. Clean and rinse the filter once again with fresh water.
If you don’t plan to use the humidifier for a long time, remove the filter from the water tank and let
it dry thoroughly. Then wrap it in protective packaging and keep it next to the humidifier in a cool,
dry and dark storage space.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Clean Air Optima CA-603 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Clean Air Optima CA-603 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Clean Air Optima CA-603

Clean Air Optima CA-603 User Manual - English - 10 pages

Clean Air Optima CA-603 User Manual - English - 10 pages

Clean Air Optima CA-603 User Manual - Dutch - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info