Initial Operation
Filling up the Heating Boiler before Use!
CAUTION:
Before the tank lock is opened the power plug must
be removed from the socket. Please make sure the
device is depressurized by pressing the steam switch.
Before unscrewing the lock (3) proceed as follows:
1. Remove the power plug from the socket.
2. Release the pressure by using the steam switch (4).
3. If the device is still warm, please wait 5 minutes before
removing the seal completely. Press the seal downwards
and turn.
WARNING:
Danger of Injury!
Please open the safety lock (3) only when no more
steam comes out of the nozzle.
4. Shake any residual water out of the kettle (1). Then fi ll the
measuring beaker (8) and pour the water into the kettle. Use
a funnel if necessary. Re-fasten the safety lock (3).
Attachment of the Individual Accessories
Brush (10) and Angle Attachment (11)
Both attachments can be joined to the nozzle attachment (12)
on the hexagonal section.
Nozzle Attachment, Hose, Cleaning and Non-woven Fabric
Attachment
1. Before attaching the accessories please look at the ope-
nings on the connecting nozzle. The pins on the accessory
must be in line with the openings of the connecting nozzle.
Push the accessory on to the device as far as it will go.
2. Turn the accessory through approximately 90° in a
clockwise direction. The accessory remains locked in this
position.
3. The nozzle attachment can be used on the hose or directly
on the device.
4. The hose (7) must be attached to the connection nozzle (2).
The nozzle attachment and the universal cleaning attach-
ment (13) can be fi xed to the end of the hose. The universal
cleaning attachment should be used either together with
the non-woven fabric attachment (9) or with the window
cleaning attachment (14). The non-woven fabric attachment
is intended for cleaning sensitive surfaces such as sofas
and armchairs.
5. The window cleaning attachment (14) is hooked under the
cleaning attachment (13).
Attachments:
Nozzle attachment: for cleaning crevices, for
example, bathtub edges etc.
Brush attachment: for areas which are diffi cult
to access.
Angle attachment: for areas which are diffi cult
to access, e.g. radiators.
Non-woven fabric attachment: protective non-woven fabric
attachment for sensitive
surfaces.
Window cleaning attachment: for window cleaning, shower
cabinets etc.
Universal cleaning attachment: for larger surfaces such as
glass panes or tiles.
Switching on the Device
Before inserting the mains lead into the socket, check
whether the voltage you intend to use complies with that of
the machine. For details see the machine label.
Only connect the machine to a properly installed safety
socket, 230 V/50 Hz.
After about 3-4 minutes the pressure in the boiler has built
up. Please press the steam switch (4) to produce steam.
Filling up the Water Boiler when using the Device
If there is no more water in the vessel no steam is emitted when
the steam switch (4) is pressed. The water has to be fi lled up
as follows:
1. Pull the power plug out of the socket!
2. Wait for approximately 5 minutes and release the resi-
dual pressure with the steam switch!
3.
WARNING:
Unscrew the safety lock (3) slowly and wait for a few
seconds before opening it completely until the excess
pressure has escaped.
4. Fill fresh water from the measuring beaker (8) by means of
the funnel into the boiler. Do not overfi ll! Do not exceed the
amount of water indicated on the measuring beaker! Take
care of water splashes that might come out of the boiler. In
order to prevent the water from splashing it should be fi lled
into the funnel slowly after the safety lock has been opened.
5. Fasten the safety lock again.
6. Insert the power plug back into the socket.
Cleaning and Maintenance
WARNING:
Cleaning and maintenance must only be carried out when the
power plug is removed from the socket.
Before putting the device away or cleaning it, it has to be
allowed to cool down completely.
Please clean the device and the accessories only with a
slightly moist cloth.
Do not use strong cleaning agents of solvents for cleaning.
In order to guarantee a long and trouble-free working life,
lime residues have to be rinsed out of the boiler once a
month. Please do not use vinegar or other anti-liming
agents.
05-DR 2930 NEU.indd 2605-DR 2930 NEU.indd 26 25.02.2009 16:19:53 Uhr25.02.2009 16:19:53 Uhr
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Clatronic dr 2930 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Clatronic dr 2930 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info